4.6 Article

Design Optimization of a Hybrid Vibration Control System for Buildings

Related references

Note: Only part of the references are listed.
Article Engineering, Civil

Inter-story seismic isolation for high-rise buildings

Davide Forcellini et al.

Summary: This paper studies inter-story seismic isolation in a 20-floor building, examining different configurations with isolation layers at various heights. The performances of each model are evaluated based on shear forces, accelerations, and drifts, demonstrating the potential of inter-story isolation as a means of base isolation.

ENGINEERING STRUCTURES (2023)

Article Construction & Building Technology

Multi-stage superelastic variable stiffness pendulum isolation system for seismic response control of bridges under near-fault earthquakes

Wenzhi Zheng et al.

Summary: A novel multi-stage superelastic variable stiffness pendulum isolator (SVSPI) is developed to improve the resilient capability of bridges by incorporating superelastic shape memory alloy (SMA) with the multi-stage variable stiffness pendulum isolator (VSPI). The numerical model for the isolator is created, and a design method based on fractional factors is suggested for parameter optimization. Case studies prove the effectiveness of the isolator and design method in controlling displacements and forces in bridges. The research provides a reliable basis for structural resilience enhancement and potential applications.

STRUCTURAL CONTROL & HEALTH MONITORING (2022)

Article Engineering, Civil

Parametric Study of SMA-based Friction Pendulum System for Response Control of Bridges under Near-Fault Ground Motions

Wen-Zhi Zheng et al.

Summary: The sensitivity study on SMA-based FPB system for response control of a three-span continuous isolated bridge showed that it can effectively reduce residual displacement and peak displacement while providing reliable recentering and energy dissipation capabilities for bridges against near-fault earthquakes.

JOURNAL OF EARTHQUAKE ENGINEERING (2021)

Review Engineering, Geological

Seismically isolated buildings in Italy: State-of-the-art review and applications

Paolo Clemente et al.

SOIL DYNAMICS AND EARTHQUAKE ENGINEERING (2019)

Article Engineering, Civil

Transforming Method of TLCD-structure to TMD-structure for Vibration Control

Chuan Fu

KSCE JOURNAL OF CIVIL ENGINEERING (2018)

Article Engineering, Civil

Optimum tuned mass damper design in frequency domain for structures

Sinan Melih Nigdeli et al.

KSCE JOURNAL OF CIVIL ENGINEERING (2017)

Article Engineering, Geological

Metaheuristic based optimization of tuned mass dampers under earthquake excitation by considering soil-structure interaction

Gebrail Bekdas et al.

SOIL DYNAMICS AND EARTHQUAKE ENGINEERING (2017)

Article Engineering, Civil

Necessity and adequacy of near-source factors for seismically isolated buildings

Muhammad Khalid Saifullah et al.

EARTHQUAKES AND STRUCTURES (2017)

Article Engineering, Civil

Comparative response and performance of base-isolated and fixed-base structures

Sarun Chimamphant et al.

EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS (2016)

Article Materials Science, Multidisciplinary

Nonlinear vibration control of a tall structure with tuned liquid column damper

Shueei-Muh Lin

MECHANICS OF ADVANCED MATERIALS AND STRUCTURES (2016)

Article Engineering, Civil

Performance limits of seismically isolated buildings under near-field earthquakes

Cenk Alhan et al.

ENGINEERING STRUCTURES (2016)

Article Engineering, Civil

Innovative modeling of tuned liquid column damper controlled structures

Alberto Di Matteo et al.

SMART STRUCTURES AND SYSTEMS (2016)

Article Mathematics, Applied

Innovative modeling of Tuned Liquid Column Damper motion

A. Di Matteo et al.

COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION (2015)

Article Construction & Building Technology

Seismic isolation of buildings for power stations considering soil-structure interaction effects

Arturo Tena-Colunga et al.

JOURNAL OF BUILDING ENGINEERING (2015)

Article Engineering, Civil

Evaluation and analytical approximation of Tuned Mass Damper performance in an earthquake environment

Alexander Tributsch et al.

SMART STRUCTURES AND SYSTEMS (2012)

Article Engineering, Geological

Shear building representations of seismically isolated buildings

Cenk Alhan et al.

BULLETIN OF EARTHQUAKE ENGINEERING (2011)

Article Engineering, Civil

Estimating optimum parameters of tuned mass dampers using harmony search

Gebrail Bekdas et al.

ENGINEERING STRUCTURES (2011)

Review Engineering, Multidisciplinary

Smart structures: Part II - Hybrid control systems and control strategies

N. R. Fisco et al.

SCIENTIA IRANICA (2011)

Article Geography, Physical

Landslides induced by the 2008 Wenchuan earthquake, Sichuan, China

Masahiro Chigira et al.

GEOMORPHOLOGY (2010)

Article Engineering, Civil

Effect of tuned mass damper on displacement demand of base-isolated structures

Tomoyo Taniguchi et al.

ENGINEERING STRUCTURES (2008)

Article Construction & Building Technology

Control of tall building vibrations by sealed tuned liquid column dampers

Markus J. Hochrainer et al.

STRUCTURAL CONTROL & HEALTH MONITORING (2006)

Article Mechanics

Tuned liquid column damper for structural control

MJ Hochrainer

ACTA MECHANICA (2005)