4.7 Article

Assessing overdiagnosis of fecal immunological test screening for colorectal cancer with a digital twin approach

Journal

NPJ DIGITAL MEDICINE
Volume 6, Issue 1, Pages -

Publisher

NATURE PORTFOLIO
DOI: 10.1038/s41746-023-00763-5

Keywords

-

Ask authors/readers for more resources

This study aimed to evaluate the proportion of overdiagnosis in population-based service screening for colorectal cancer (CRC) with the fecal immunochemical test (FIT). Using the digital twin method, the researchers developed parameters to predict CRC cases containing overdiagnosis, and the results showed that the extent of overdiagnosis resulting from FIT screening is 4.16%. This suggests that the harm done to population-based FIT service screening is negligible.
Evaluating the magnitude of overdiagnosis associated with stool-based service screening for colorectal cancer (CRC) beyond a randomized controlled trial is often intractable and understudied. We aim to estimate the proportion of overdiagnosis in population-based service screening programs for CRC with the fecal immunochemical test (FIT). The natural process of overdiagnosis-embedded disease was first built up to learn transition parameters that quantify the pathway of non-progressive and progressive screen-detected cases calibrated with sensitivity, while also taking competing mortality into account. The Markov algorithms were then developed for estimating these transition parameters based on Taiwan FIT service CRC screening data on 5,417,699 residents aged 50-69 years from 2004 to 2014. Following the digital twin design with the parallel universe structure for emulating the randomized controlled trial, the screened twin, mirroring the control group without screening, was virtually recreated by the application of the above-mentioned trained parameters to predict CRC cases containing overdiagnosis. The ratio of the predicted CRCs derived from the screened twin to the observed CRCs of the control group minus 1 was imputed to measure the extent of overdiagnosis. The extent of overdiagnosis for invasive CRCs resulting from FIT screening is 4.16% (95% CI: 2.61-5.78%). The corresponding figure is increased to 9.90% (95% CI: 8.41-11.42%) for including high grade dysplasia (HGD) and further inflated to 15.83% (95% CI: 15.23-16.46%) when the removal adenoma is considered. The modest proportion of overdiagnosis modelled by the digital twin method, dispensing with the randomized controlled trial design, suggests the harm done to population-based FIT service screening is negligible.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available