4.5 Article

Development and Validation of the CVP Score: A Cross-Sectional Study in Greece

Related references

Note: Only part of the references are listed.
Review Anesthesiology

The contemporary pulmonary artery catheter. Part 1: placement and waveform analysis

I. T. Bootsma et al.

Summary: This review discusses the history and evolution of classical pulmonary artery catheter (PAC) as well as the differences between intermittent and continuous measurements. It also delves into insertion techniques, waveform interpretation, the interaction of waveforms with respiratory cycle and airway pressure, and potential pitfalls in waveform analysis.

JOURNAL OF CLINICAL MONITORING AND COMPUTING (2021)

Article Multidisciplinary Sciences

Feasibility and beneficial effects of an early goal directed therapy after cardiac arrest: evaluation by conductance method

Ole Broch et al.

Summary: This study investigated the feasibility and impact of EGDT on myocardial damage and function after cardiac resuscitation in a translational pig model. The EGDT group showed a significant decrease in lactate levels and improved systolic myocardial function, indicating the potential benefits of implementing EGDT algorithms in post cardiac arrest care. Further investigation is needed to fully understand the impact and implementation of EGDT after cardiac arrest.

SCIENTIFIC REPORTS (2021)

Article Anesthesiology

Is measurement of central venous pressure required to estimate systemic vascular resistance? A retrospective cohort study

Chahyun Oh et al.

Summary: The study retrospectively calculated systemic vascular resistance (SVR) using fixed and randomly changing values of central venous pressure (CVP) in patients who underwent neurological and cardiac surgery. It found that using a fixed CVP of 10 mmHg resulted in the highest accuracy of SVR estimation, with mean absolute percentage errors of 6.3% and 5.7% in neurological and cardiac surgery, respectively. The results suggest that in certain conditions, estimating SVR from a fixed CVP value can be accurate without losing trending ability.

BMC ANESTHESIOLOGY (2021)

Review Critical Care Medicine

Predictors to Intravenous Fluid Responsiveness

Jorge Ivan Alvarado Sanchez et al.

JOURNAL OF INTENSIVE CARE MEDICINE (2018)

Review Anesthesiology

Central venous pressure: soon an outcome-associated matter

Soren Sondergaard et al.

CURRENT OPINION IN ANESTHESIOLOGY (2016)

Article Nursing

Designing and Validity Evaluation of Quality of Nursing Care Scale in Intensive Care Units

Mashaalah Zeraati et al.

JOURNAL OF NURSING MEASUREMENT (2014)

Article Critical Care Medicine

Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock, 2012

R. P. Dellinger et al.

INTENSIVE CARE MEDICINE (2013)

Article Pharmacology & Pharmacy

Validity and reliability of measurement instruments used in research

Carole L. Kimberlin et al.

AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY (2008)

Article Critical Care Medicine

Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge

David Osman et al.

CRITICAL CARE MEDICINE (2007)