4.6 Article

Economic analysis of remote monitoring in patients with implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators in the Trento area, Italy

Journal

FRONTIERS IN CARDIOVASCULAR MEDICINE
Volume 10, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fcvm.2023.1151167

Keywords

remote monitoring; heart failure; hf; cardiac implantable electronic device; CIED; Italy

Ask authors/readers for more resources

This retrospective study assessed the clinical and economic outcomes of remote monitoring (RM) vs. standard monitoring (SM) in patients with cardiac implantable electronic devices (CIED). The study found that RM can reduce mortality rate and cardiovascular-related hospitalizations, and it can also result in cost savings for both payers and hospitals.
IntroductionRemote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). MethodsClinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. ResultsIn the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of -euro4,771 and -euro6,752 per patient in 2 years, in the payer and hospital perspective, respectively. ConclusionRM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available