4.7 Article

An ultralow power wearable vital sign sensor using an electromagnetically reactive near field

Related references

Note: Only part of the references are listed.
Review Biotechnology & Applied Microbiology

Wearable biosensors for human fatigue diagnosis: A review

Jingyang Zhang et al.

Summary: Fatigue has significant adverse effects on human health, necessitating timely, portable, and accurate fatigue diagnosis. Wearable biosensors, which collect biomarkers from biofluids and transmit detection signals wirelessly in real-time, have attracted attention. However, detection performance limits the wide applicability of wearable fatigue diagnosis. This article discusses the application of wearable biosensors in fatigue diagnosis, exploring the potential of different biofluids and addressing current limitations and advancements in biochemical reaction and data communication modules. Challenges and opportunities for wearable fatigue diagnosis in the future are also discussed.

BIOENGINEERING & TRANSLATIONAL MEDICINE (2023)

Article Chemistry, Analytical

Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement

Ting-Wei Wang et al.

Summary: This study proposes an AI-based intelligent single-channel bio-impedance system for personalized blood pressure (BP) monitoring. The system extracts significant BP features from bio-impedance signals using an ultra-lightweight AI algorithm, and demonstrates good BP accuracy in human trials. The system has low hardware complexity and is suitable for wearable applications.

BIOSENSORS-BASEL (2022)

Article Nanoscience & Nanotechnology

Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos

Dmitry Kireev et al.

Summary: Continuous monitoring of arterial blood pressure in non-clinical settings is crucial for understanding various health conditions, including cardiovascular diseases. This study introduces a wearable blood pressure monitoring platform that utilizes atomically thin graphene electronic tattoos as interfaces. The platform enables highly accurate and non-invasive continuous monitoring, with a longer monitoring period than previous studies.

NATURE NANOTECHNOLOGY (2022)

Article Cardiac & Cardiovascular Systems

Heart Disease and Stroke Statistics-2021 Update A Report From the American Heart Association

Salim S. Virani et al.

Summary: The American Heart Association, in partnership with the National Institutes of Health, publishes annual statistics on heart disease, stroke, and cardiovascular risk factors, including the impact of health behaviors and factors on cardiovascular health. The Statistical Update covers a range of clinical heart and circulatory conditions, providing data on quality of care, procedures, and economic costs. It serves as a critical resource for various stakeholders seeking the best available data on these factors and conditions.

CIRCULATION (2021)

Article Multidisciplinary Sciences

A novel art of continuous noninvasive blood pressure measurement

Juergen Fortin et al.

Summary: The continuous noninvasive blood pressure measurement system CNAP2GO presents a potential breakthrough in patient monitoring, directly measuring blood pressure using volume control technique for integration in small wearable sensors. CNAP2GO demonstrated excellent blood pressure measurement performance during surgeries, with the capability to derive cardiac output and other hemodynamic variables. The system can self-calibrate and be miniaturized for wearable use, offering significant promise for blood pressure monitoring in clinical settings.

NATURE COMMUNICATIONS (2021)

Article Computer Science, Information Systems

PCA-Based Multi-Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects

Jing Liu et al.

Summary: The study proposed an improved multi-wavelength PPG algorithm based on principal component analysis (PCA) to calculate arteriolar PTT by matching statistical decomposition results with arterial pulse and capillary pulse, enhancing feature robustness, and using PCA-derived MA component to identify and exclude MA-contaminated segments.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2021)

Article Engineering, Biomedical

An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers

Juliane R. Sempionatto et al.

Summary: This study presents a smart skin-worn device that can monitor blood pressure, heart rate, and various biomarkers, allowing for the capture of physiological effects of food intake and exercise.

NATURE BIOMEDICAL ENGINEERING (2021)

Article Multidisciplinary Sciences

Flexible Doppler ultrasound device for the monitoring of blood flow velocity

Fengle Wang et al.

Summary: This study introduces a flexible Doppler ultrasound device for the continuous monitoring of the absolute velocity of blood flow in deeply embedded arteries, demonstrating accurate measurement capabilities.

SCIENCE ADVANCES (2021)

Article Multidisciplinary Sciences

A wearable patch for continuous analysis of thermoregulatory sweat at rest

Hnin Yin Yin Nyein et al.

Summary: The study presents wearable microfluidics-based patches for continuous sweat monitoring at rest, enabling detection of pH, Cl-, and levodopa for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson's disease, thus allowing for continuous and autonomous monitoring of body physiology at rest.

NATURE COMMUNICATIONS (2021)

Article Biotechnology & Applied Microbiology

Temporal profiling of cytokines in passively expressed sweat for detection of infection using wearable device

Badrinath Jagannath et al.

Summary: This study demonstrates the potential of using passive sweat for tracking human body's inflammatory response, with the development of a wearable SWEATSENSER device for real-time monitoring of cytokines. The device shows high accuracy and specificity in detecting inflammatory markers, making it a promising tool for noninvasive tracking of host immune response biomarkers.

BIOENGINEERING & TRANSLATIONAL MEDICINE (2021)

Article Biotechnology & Applied Microbiology

Tracking metabolic responses based on macronutrient consumption: A comprehensive study to continuously monitor and quantify dual markers (cortisol and glucose) in human sweat using WATCH sensor

Madhavi Pali et al.

Summary: The research demonstrates the capability of the WATCH sensor in monitoring cortisol and glucose in human sweat and its relationship with macronutrient consumption. The importance of this technology lies in capturing the body's metabolic and endocrinal responses to dietary triggers, leading to enhanced lifestyle management. The statistical robustness of the WATCH sensor was confirmed through various analyses, showing comparable results to standard reference methods.

BIOENGINEERING & TRANSLATIONAL MEDICINE (2021)

Review Medicine, General & Internal

Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring

Manish Hosanee et al.

JOURNAL OF CLINICAL MEDICINE (2020)

Article Cardiac & Cardiovascular Systems

Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation

Yutao Guo et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2019)

Article Health Care Sciences & Services

Contactless cardiac arrest detection using smart devices

Justin Chan et al.

NPJ DIGITAL MEDICINE (2019)

Article Engineering, Biomedical

Noninvasive Blood Pressure Estimation Using Ultrasound and Simple Finite Element Models

Aaron M. Zakrzewski et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2018)

Article Cell Biology

Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method

Anand Chandrasekhar et al.

SCIENCE TRANSLATIONAL MEDICINE (2018)

Article Engineering, Biomedical

Monitoring of the central blood pressure waveform via a conformal ultrasonic device

Chonghe Wang et al.

NATURE BIOMEDICAL ENGINEERING (2018)

Article Biochemical Research Methods

Optical blood pressure estimation with photoplethysmography and FFT-based neural networks

Xiaoman Xing et al.

BIOMEDICAL OPTICS EXPRESS (2016)

Article Multidisciplinary Sciences

Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin

Jeonghyun Kim et al.

SCIENCE ADVANCES (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessing heating distribution by therapeutic ultrasound on bone phantoms and in vitro human samples using infrared thermography

Gabriella Sellani et al.

JOURNAL OF THERAPEUTIC ULTRASOUND (2016)

Article Anesthesiology

Respiration Signals from Photoplethysmography

Lena M. Nilsson

ANESTHESIA AND ANALGESIA (2013)

Article Primary Health Care

Healthy Lifestyle Habits and Mortality in Overweight and Obese Individuals

Eric M. Matheson et al.

JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE (2012)

Article Cardiac & Cardiovascular Systems

Pulse Wave Analysis of the Aortic Pressure Waveform in Severe Left Ventricular Systolic Dysfunction

Scott J. Denardo et al.

CIRCULATION-HEART FAILURE (2010)

Article Computer Science, Artificial Intelligence

A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis

Alexandros Pantelopoulos et al.

IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART C-APPLICATIONS AND REVIEWS (2010)

Article Medicine, General & Internal

The impact of advance care planning on end of life care in elderly patients: randomised controlled trial

Karen M. Detering et al.

BMJ-BRITISH MEDICAL JOURNAL (2010)

Article Medicine, General & Internal

Prognostic accuracy of day versus night ambulatory blood pressure:: a cohort study

Jose Boggia et al.

LANCET (2007)

Review Peripheral Vascular Disease

Contour analysis of the photoplethysmographic pulse measured at the finger

Sandrine C. Millasseau et al.

JOURNAL OF HYPERTENSION (2006)

Article Medicine, General & Internal

Current concepts: Ambulatory blood-pressure monitoring

Thomas G. Pickering et al.

NEW ENGLAND JOURNAL OF MEDICINE (2006)

Review Critical Care Medicine

Agonal respirations during cardiac arrest

TD Rea

CURRENT OPINION IN CRITICAL CARE (2005)

Article Engineering, Biomedical

A new probe for ankle systolic pressure measurement using Photoplethysmography (PPG)

R Jönsson et al.

ANNALS OF BIOMEDICAL ENGINEERING (2005)

Article Biophysics

Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method

S Loukogeorgakis et al.

PHYSIOLOGICAL MEASUREMENT (2002)

Article Medicine, General & Internal

Antecedents to hospital deaths

KM Hillman et al.

INTERNAL MEDICINE JOURNAL (2001)