Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm

Journal

MATHEMATICS
Volume 11, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/math11040970

Keywords

inertial measurement unit; accelerometer; gyroscope; magnetometer; electro-goniometer; joint angle; rigid body; sensor fusion; Madgwick filter; Kalman filter

Categories

Ask authors/readers for more resources

In physical therapy, motion-tracking devices using cameras and inertial measurement units (IMUs) are commonly used. This study developed a 3D rigid body to estimate elbow joint angles using three IMUs and a fusion algorithm incorporating the Madgwick filter. The proposed algorithm exhibited higher accuracy and stability compared to the IMU manufacturer's algorithm, with a maximum RMSE of 0.46 degrees.
In physical therapy, exercises improve range of motion, muscle strength, and flexibility, where motion-tracking devices record motion data during exercises to improve treatment outcomes. Cameras and inertial measurement units (IMUs) are the basis of these devices. However, issues such as occlusion, privacy, and illumination can restrict vision-based systems. In these circumstances, IMUs may be employed to focus on a patient's progress quantitatively during their rehabilitation. In this study, a 3D rigid body that can substitute a human arm was developed, and a two-stage algorithm was designed, implemented, and validated to estimate the elbow joint angle of that rigid body using three IMUs and incorporating the Madgwick filter to fuse multiple sensor data. Two electro-goniometers (EGs) were linked to the rigid body to verify the accuracy of the joint angle measuring algorithm. Additionally, the algorithm's stability was confirmed even in the presence of external acceleration. Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46 degrees. Using the IMU manufacturer's (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97 degrees. For the fourth trial, joint angles were also calculated with external acceleration, and the RMSE was 0.996 degrees. In all cases, the joint angles were within therapeutic limits.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available