This research proposes an optimal robotic arm speed shape in neurological surgery to minimise a cost functional that uses an adaptive scheme to determine the brain tissue force. Until now, there have been no studies or theories on the shape of the robotic arm speed in such a context. The authors have applied a robotic arm with optimal speed control in neurological surgery. The results of this research are as follows: In this article, the authors propose a control scheme that minimises a cost functional which depends on the position error, trajectory speed and brain tissue force. This work allowed us to achieve an optimal speed shape or trajectory to reduce brain retraction damage during surgery. The authors have reached two main conclusions. The first is that optimal control techniques are very well suited for robotic control of neurological surgery. The second conclusion is that several studies on functional cost parameters are needed to achieve the best trajectory speed of the robotic arm. These studies could attempt to optimise the functional cost parameters and provide a mechanical characterisation of brain tissue based on real data.
This research proposes an optimal robotic arm speed shape in neurological surgery to minimise a cost functional that uses an adaptive scheme to determine the brain tissue force. Until now, there have been no studies or theories on the shape of the robotic arm speed in such a context. The authors have applied a robotic arm with optimal speed control in neurological surgery. The results of this research are as follows: In this article, the authors propose a control scheme that minimises a cost functional which depends on the position error, trajectory speed and brain tissue force. This work allowed us to achieve an optimal speed shape or trajectory to reduce brain retraction damage during surgery. The authors have reached two main conclusions. The first is that optimal control techniques are very well suited for robotic control of neurological surgery. The second conclusion is that several studies on functional cost parameters are needed to achieve the best trajectory speed of the robotic arm. These studies could attempt to optimise the functional cost parameters and provide a mechanical characterisation of brain tissue based on real data.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available