4.5 Article

Automated measurement of penile curvature using deep learning-based novel quantification method

Journal

FRONTIERS IN PEDIATRICS
Volume 11, Issue -, Pages -

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fped.2023.1149318

Keywords

penile curvature; artificial intelligence; machine learning; YOLO; UNET; HRNet; hypospadias; chordee

Categories

Ask authors/readers for more resources

This study developed a reliable, automated deep learning-based method to accurately measure penile curvature using 2-dimensional images. A set of 913 images of penile curvature with varying configurations was generated using 3D-printed models. The method involved localized cropping, segmentation, and landmark prediction using machine learning models.
ObjectiveDevelop a reliable, automated deep learning-based method for accurate measurement of penile curvature (PC) using 2-dimensional images. Materials and methodsA set of nine 3D-printed models was used to generate a batch of 913 images of penile curvature (PC) with varying configurations (curvature range 18 degrees to 86 degrees). The penile region was initially localized and cropped using a YOLOv5 model, after which the shaft area was extracted using a UNet-based segmentation model. The penile shaft was then divided into three distinct predefined regions: the distal zone, curvature zone, and proximal zone. To measure PC, we identified four distinct locations on the shaft that reflected the mid-axes of proximal and distal segments, then trained an HRNet model to predict these landmarks and calculate curvature angle in both the 3D-printed models and masked segmented images derived from these. Finally, the optimized HRNet model was applied to quantify PC in medical images of real human patients and the accuracy of this novel method was determined. ResultsWe obtained a mean absolute error (MAE) of angle measurement <5 degrees for both penile model images and their derivative masks. For real patient images, AI prediction varied between 1.7 degrees (for cases of similar to 30 degrees PC) and approximately 6 degrees (for cases of 70 degrees PC) compared with assessment by a clinical expert. DiscussionThis study demonstrates a novel approach to the automated, accurate measurement of PC that could significantly improve patient assessment by surgeons and hypospadiology researchers. This method may overcome current limitations encountered when applying conventional methods of measuring arc-type PC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available