4.5 Article

Characterization of Oxygen Nanobubbles and In Vitro Evaluation of Retinal Cells in Hypoxia

Journal

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/tvst.12.2.16

Keywords

oxygen nanobubbles; hypoxia; retina; safety and efficacy; treatment

Categories

Ask authors/readers for more resources

This study aims to develop an oxygen delivery system using oxygen nanobubbles (ONBs) to mitigate retinal ischemia during severe hypoxia. The results show that ONBs have excellent oxygen holding and release properties, as well as being sterile, stable, and non-toxic.
Purpose: Vein or artery occlusion causes a hypoxic environment by preventing oxygen delivery and diffusion to tissues. Diseases such as retinal vein occlusion, central retinal artery occlusion, or diabetic retinopathy create a stroke-type condition that leads to functional blindness in the effected eye. We aim to develop an oxygen delivery system consisting of oxygen nanobubbles (ONBs) that can mitigate retinal ischemia during a severe hypoxic event such as central retinal artery occlusion. Methods: ONBs were synthesized to encapsulate oxygen saturated molecular medical grade water. Stability, oxygen release, biocompatibility, reactive oxygen species, super-oxide, MTT, and terminal uridine nick-end labeling assays were performed. Cell viability was evaluated, and safety experiments were conducted in rabbits. Results: The ONBs were approximately 220 nm in diameter, with a zeta potential of -58.8 mV. Oxygen release studies indicated that 74.06 & mu;g of O2 is released from the ONBs after 12 hours at 37 & DEG;C. Cell studies indicated that ONBs are safe and cells are viable. There was no significant increase in reactive oxygen species, superoxide, or double -stranded DNA damage after ONB treatment. ONBs preserve mitochondrial function and viability. Histological sections from rabbit eyes indicated that ONBs were not toxic. Conclusions: The ONBs proposed have excellent oxygen holding and release properties to mitigate ischemic conditions in the retina. They are sterile, stable, and nontoxic. Translation Relevance: ONB technology was evaluated for its physical properties, oxygen release, sterility, stability, and safety. Our results indicate that ONBs could be a viable treatment approach to mitigate hypoxia during ischemic conditions in the eye upon timely administration.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available