4.6 Article

Mechanistic Studies on the Self-Assembly of PLGA Patchy Particles and Their Potential Applications in Biomedical Imaging

Journal

LANGMUIR
Volume 32, Issue 31, Pages 7929-7942

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.langmuir.6b02177

Keywords

-

Funding

  1. NSF [CBET-1348112]
  2. GMU Seed Grant [130978]
  3. CONICYT
  4. CONICYT + PAI/Concurso Nacional Tesis de Doctorado en la Empresa Grant [781413007]
  5. Fraunhofer Chile Research, Innova-Chile CORFO Grant [FCR-CSB 09CEII-6991]
  6. RED CYTED [214RT0482]
  7. Anillo Cientifico [ACT1107]
  8. Center for the Development of Nanoscience and Nanotechnology (CEDENNA)-BASAL Grant [FB0807]
  9. FONDECYT [1161438 CONICYT-Chile]

Ask authors/readers for more resources

Currently, several challenges prevent poly(lactic-co-glycolic acid) (PLGA) particles from reaching clinical settings. Among these is a lack of understanding of the molecular mechanisms involved in the formation of these particles. We have been studying in depth the formation of patchy polymeric particles. These particles are made of PLGA and lipid polymer functional groups. They have unique patch core shell structural features: hollow or solid hydrophobic cores and a patchy surface. Previously, we identified the shear stress as the most important parameter in a patchy particle's formation. Here, we investigated in detail the role of shear stress in the patchy particle's internal and external structure using an integrative experimental and computational approach. By cross-sectioning the multi patch particles, we found lipid-based structures embedded in the entire PLGA matrix, which represents a unique finding in the PLGA field. By developing novel computational fluid dynamics and molecular dynamics simulations, we found that the shear stress determines the internal structure of the patchy particles. Equally important, we discovered that these particles emit a photoacoustic (PA) signal in the optical clinical imaging window. Our results show that particles with multiple patches emit a higher PA signal than single-patch particles. This phenomenon most likely is due to the fact that multipatchy particles absorb more heat than single-patchy particles as shown by differential scanning calorimetry analysis. Furthermore, we demonstrated the use of patchy polymeric particles as photoacoustic molecular probes both in vitro and in vivo studies. The fundamental studies described here will help us to design more effective PLGA carriers for a number of medical applications as well as to accelerate their medical translation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available