4.6 Article

A Chest-Conformable, Wireless Electro-Mechanical E-Tattoo for Measuring Multiple Cardiac Time Intervals

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals

David J. Lin et al.

Summary: This paper proposes a novel denoising pipeline to remove vehicle-vibration artifacts from corrupted seismocardiogram (SCG) beats for accurate fiducial point detection.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2022)

Article Multidisciplinary Sciences

Graphene e-tattoos for unobstructive ambulatory electrodermal activity sensing on the palm enabled by heterogeneous serpentine ribbons

Hongwoo Jang et al.

Summary: This article presents a novel heterogeneous serpentine ribbons design that enables a stretchable and robust interface between graphene e-tattoos and printed circuit boards, allowing for ambulatory electrodermal activity monitoring on the palm. The addition of a soft interlayer improves the strain concentration issue, and a new event selection policy validates the accuracy of the EDA sensor.

NATURE COMMUNICATIONS (2022)

Proceedings Paper Engineering, Electrical & Electronic

A Synthetic Seismocardiogram and Electrocardiogram Generator Phantom

Mohammad Nikbakht et al.

Summary: This study proposes a synthetic SCG and ECG generator system for data collection in unsafe or inconvenient environments. The system is validated using real signals and demonstrates high input-output correlations. Therefore, the system is able to generate realistic signals with clinically relevant amplitudes in participant-free environments.

2022 IEEE SENSORS (2022)

Article Computer Science, Information Systems

Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients

Beren Semiz et al.

Summary: This study proposes a wearable patch mounted on the mid-sternum to continuously capture seismocardiogram (SCG) and electrocardiogram (ECG) signals for predicting stroke volume (SV) in patients undergoing major surgery. Signal processing techniques were used to derive SV from the signals captured by the wearable patch and compare it to values obtained by the Transesophageal Doppler (TED). The results showed a substantial correlation and relatively low error between the predicted and reference SV values, indicating the potential of the wearable-based methodology as an alternative to TED for continuous patient monitoring and peri-operative fluid management.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2021)

Article Engineering, Biomedical

A Novel Wearable Device for Continuous Temperature Monitoring Fever Detection

Nishant Verma et al.

Summary: Continuous temperature monitoring in high-risk patients using a wearable device like Verily Patch can reliably estimate body temperature and early detect fevers, leading to better clinical outcomes through timely intervention.

IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE (2021)

Article Computer Science, Information Systems

A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals

Jonathan Zia et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2020)

Article Computer Science, Information Systems

Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace

Jonathan Zia et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2020)

Article Cardiac & Cardiovascular Systems

Single lead patch recording systems: The expanding role for long-term ECG recording systems

N. Ben-Dov et al.

JOURNAL OF ELECTROCARDIOLOGY (2019)

Meeting Abstract Cardiac & Cardiovascular Systems

DOES NON-INVASIVE CARDIAC OUTPUT MONITORING (NICOM) CORRELATE WITH STANDARD INVASIVE HEMODYNAMIC MONITORING IN PATIENTS WITH ACUTE DECOMPENSATED HEART FAILURE?

Aniket Rali et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2019)

Article Materials Science, Multidisciplinary

Modular and Reconfigurable Wireless E-Tattoos for Personalized Sensing

Hyoyoung Jeong et al.

ADVANCED MATERIALS TECHNOLOGIES (2019)

Article Computer Science, Information Systems

Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation

Md Mobashir Hasan Shandhi et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2019)

Article Multidisciplinary Sciences

Definition of Fiducial Points in the Normal Seismocardiogram

Kasper Sorensen et al.

SCIENTIFIC REPORTS (2018)

Review Chemistry, Multidisciplinary

Monitoring of Vital Signs with Flexible and Wearable Medical Devices

Yasser Khan et al.

ADVANCED MATERIALS (2016)

Article Chemistry, Multidisciplinary

Stretchable E-Skin Apexcardiogram Sensor

Insang You et al.

ADVANCED MATERIALS (2016)

Editorial Material Cardiac & Cardiovascular Systems

Telemedicine Helps Cardiologists Extend Their Reach

Bridget M. Kuehn

CIRCULATION (2016)

Article Engineering, Biomedical

A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables

Mozziyar Etemadi et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2016)

Article Chemistry, Multidisciplinary

Cut-and-Paste Manufacture of Multiparametric Epidermal Sensor Systems

Shixuan Yang et al.

ADVANCED MATERIALS (2015)

Article Neurosciences

Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects

M. Di Rienzo et al.

AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL (2013)

Article Materials Science, Multidisciplinary

The effects of encapsulation on deformation behavior and failure mechanisms of stretchable interconnects

Yung-Yu Hsu et al.

THIN SOLID FILMS (2011)

Review Cardiac & Cardiovascular Systems

Cardiac auscultation: Rediscovering the lost art

Michael A. Chizner

CURRENT PROBLEMS IN CARDIOLOGY (2008)

Article Engineering, Electrical & Electronic

Design of metal interconnects for stretchable electronic circuits

Mario Gonzalez et al.

MICROELECTRONICS RELIABILITY (2008)

Article Biophysics

Novel dry electrodes for ECG monitoring

Anna Gruetzmann et al.

PHYSIOLOGICAL MEASUREMENT (2007)