4.8 Article

A triboelectric nanogenerator-based tactile sensor array system for monitoring pressure distribution inside prosthetic limb

Journal

NANO ENERGY
Volume 111, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.nanoen.2023.108397

Keywords

Pressure sensor; Prosthetic socket; Triboelectric nanogenerator; Electrospinning; Self -powered; Tactile sensor

Ask authors/readers for more resources

This study proposes a self-powered triboelectric nanogenerator (TENG) based flexible tactile sensor array system for real-time monitoring of pressure distribution inside a prosthetic socket. The sensor is made of biocompatible PDMS polymer and PCL nanofiber membranes as triboelectric materials, providing high stability and low cost. Integration of the sensor array within a prosthetic device enables real-time monitoring of pressure distribution during gait simulation.
In the prosthetic field, quantifying interfacial pressure distribution between the amputee's residual limb and the socket's internal environment is imperative for developing new technologies. However, the commercially available pressure sensors have several disadvantages, namely external power supply requirements, low stability, high cost, and complexities related to integrating the sensor system into prosthetic devices. Herein, we propose a self-powered triboelectric nanogenerator (TENG) based flexible tactile sensor array system to monitor prosthetic socket internal pressure distribution in real-time. The proposed sensor consists of biocompatible poly-dimethylsiloxane (PDMS) polymer and polycaprolactone (PCL) nanofiber membranes as triboelectric materials. The biodegradable PCL nanofiber membrane, fabricated via a scalable and cost-effective electrospinning process, possesses a high surface area-to-volume ratio, facilitating enhanced charge generation during triboelectrification. The as-fabricated TENG-based tactile sensor is highly stable up to 10,000 cycles. Furthermore, the voltage of the tactile sensor is independent of different temperature and humidity values, demonstrating the stability of the sensor under various environmental conditions. Finally, we successfully integrated the tactile sensor array within a prosthetic device to monitor real-time pressure distribution inside the prosthetic socket during gait simulation. We believe that the proposed novel design provides a new dimension for the rapid development of self-powered, low-cost, and highly stable pressure monitoring systems with considerable potential for commercialization.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available