Evaluation of Surgeon-Performed Ultrasonography With or Without Contrast Enhancement vs Scintigraphy in Patients With Primary Hyperparathyroidism

Journal

JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY
Volume 149, Issue 6, Pages 531-539

Publisher

AMER MEDICAL ASSOC
DOI: 10.1001/jamaoto.2023.0389

Keywords

-

Ask authors/readers for more resources

This study investigated whether surgeon-performed ultrasonography is as effective as scintigraphy in localizing pathological parathyroid glands in patients with primary hyperparathyroidism. The results showed that conventional ultrasonography by an experienced parathyroid surgeon-sonographer was noninferior to scintigraphy and may be considered as a valid first-line imaging modality.
IMPORTANCE Scintigraphy and ultrasonography are common imaging modalities for the preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism. When comparing the 2 modalities, the benefits of ultrasonography in terms of convenience, patient comfort, duration, cost, and lack of radiation should be taken into account. OBJECTIVE To investigate whether surgeon-performed ultrasonography, with or without contrast-enhanced ultrasonography (CEUS), is noninferior to scintigraphy for localizing pathological parathyroid glands in patients with primary hyperparathyroidism. DESIGN, SETTING, AND PARTICIPANTS Prospective, paired, noninferiority cohort study performed at a high-volume tertiary referral center for parathyroidectomy with blinded examiners and a 6-month follow-up. Participants were adults (age >= 18 years) referred for parathyroidectomy due to primary hyperparathyroidism. Of 207 eligible patients, 35 were excluded, leaving 172 enrolled in the study. Inclusion lasted from September 2019 until February 2021. Follow-up ended in December 2021. EXPOSURES (99m)Technetium-pertechnetate/(99m)technetium-sestamibi subtraction scintigraphy with (99m)technetium-sestamibi single-photon emission computed tomography/computed tomography, followed by surgeon-performed ultrasonography and CEUS. MAIN OUTCOMES AND MEASURES The sensitivity of each imaging modality in localizing pathological parathyroid glands, calculated on a per-quadrant and a per-patient basis, respectively. The a priori noninferiority margin was a lower 95% confidence limit for the difference in sensitivity not falling below -10%. RESULTS Out of 172 participants, 139 (80.8%) were women, the median (range) age was 65 (24-87) years, and the median (IQR) follow-up was 200.5 (181-280.25) days. Quadrant sensitivity (95% CI) was 70.9% (63.2%-78.5%) for ultrasonography, 68.4% (60.4%-76.5%) for ultrasonography plus CEUS, and 67.0% (60.0%-74.0%) for scintigraphy. The sensitivity difference (95% CI) compared with scintigraphy was 3.9% (-4.1% to 11.8%) for ultrasonography and 1.5% (-6.4% to 9.3%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Per-patient sensitivity was 81.4% (74.8%-86.9%) for ultrasonography and 79.1% (72.2%-84.9%) for both scintigraphy and ultrasonography plus CEUS. The sensitivity difference compared with scintigraphy was 2.3% (-6.8% to 11.4%) for ultrasonography and 0.0% (-9.1% to 9.1%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. CONCLUSIONS AND RELEVANCE In this cohort study, conventional ultrasonography by an experienced parathyroid surgeon-sonographer was noninferior to scintigraphy and may constitute a valid first-line imaging modality in patients with primary hyperparathyroidism, even without the addition of CEUS. Further imaging should be reserved for cases that are equivocal or nonlocalizing on ultrasonography.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available