4.7 Article

Simultaneous determination of 2-(3-hydroxy-5-phosphonooxymethyl-2-methyl-4-pyridyl)-1,3-thiazolidine-4-carboxylic acid and main plasma aminothiols by HPLC-UV based method

Journal

SCIENTIFIC REPORTS
Volume 13, Issue 1, Pages -

Publisher

NATURE PORTFOLIO
DOI: 10.1038/s41598-023-36548-9

Keywords

-

Ask authors/readers for more resources

This report presents a method for simultaneous determination of plasma HPPTCA and total low molecular-weight thiols content. The assay is based on HPLC-UV, involving disulfides reduction, derivatization, and sample deproteinization. The HPLC-UV assay provides a complementary tool for routine clinical analysis and facilitates further studies on the role of aminothiols and HPPTCA in living systems.
The report presents the first method for simultaneous determination of plasma 2-(3-hydroxy-5-phosphonooxymethyl-2-methyl-4-pyridyl)-1,3-thiazolidine-4-carboxylic acid (HPPTCA), an adduct of cysteine (Cys) and active form of vitamin B6 pyridoxal 5 '-phosphate (PLP), as well as total low molecular-weight thiols content, including Cys, homocysteine (Hcy), cysteinyl-glycine (Cys-Gly), and glutathione (GSH). The assay is based on high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) and involves disulfides reduction with tris(2-carboxyethyl)phosphine (TCEP), derivatization with 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT) followed by sample deproteinization with perchloric acid (PCA). The chromatographic separation of obtained stable UV-absorbing derivatives is achieved on ZORBAX SB-C18 (150 x 4.6 mm, 5.0 mu m) column using gradient elution with eluent consisted of 0.1 mol/L trichloroacetic acid (TCA), pH 1.7 and acetonitrile (ACN), delivered at a flow rate 1 mL/min. Under these conditions, the analytes are separated within 14 min at room temperature, and quantified by monitoring at 355 nm. Regarding HPPTCA, the assay linearity was demonstrated within a 1-100 mu mol/L in plasma and the lowest concentration on the calibration curve was recognized as the limit of quantification (LOQ). The accuracy ranged from 92.74 to 105.57% and 95.43 to 115.73%, while precision varied from 2.48 to 6.99% and 0.84 to 6.98% for intra- and inter-day measurements, respectively. The utility of the assay was proved by application to plasma samples delivered by apparently healthy donors (n = 18) in which the HPPTCA concentration ranged from 19.2 to 65.6 mu mol/L. The HPLC-UV assay provides complementary tool for routine clinical analysis, facilitating further studies on the role of aminothiols and HPPTCA in living systems.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available