4.5 Article

MAX IV Laboratory

Related references

Note: Only part of the references are listed.
Article Instruments & Instrumentation

MAXPEEM: a spectromicroscopy beamline at MAX IV laboratory

Yuran Niu et al.

Summary: MAXPEEM is a dedicated photoemission electron microscopy beamline at MAX IV Laboratory, featuring an aberration-corrected spectroscopic photoemission and low-energy electron microscope (AC-SPELEEM). This powerful instrument offers a wide range of complementary techniques with a single-digit nanometer spatial resolution for structure, chemistry, and magnetic sensitivities. The beamline can deliver a high photon flux of >= 10(15) photons s(-1) (0.1% bandwidth)(-1) in the range 30-1200 eV, with full control of polarization.

JOURNAL OF SYNCHROTRON RADIATION (2023)

Article Chemistry, Multidisciplinary

Ultralarge Virtual Screening Identifies SARS-CoV-2 Main Protease Inhibitors with Broad-Spectrum Activity against Coronaviruses

Andreas Luttens et al.

Summary: Developing drug inhibitors targeting SARS-CoV-2 is crucial for saving lives and preparing for future outbreaks. Two virtual screening strategies were explored, resulting in the identification of compounds with inhibitory effects, including one compound with promising antiviral activity.

JOURNAL OF THE AMERICAN CHEMICAL SOCIETY (2022)

Article Multidisciplinary Sciences

Defect-driven antiferromagnetic domain walls in CuMnAs films

Sonka Reimers et al.

Summary: This study reveals that the antiferromagnetic (AF) domain structure in CuMnAs thin films is dominated by nanoscale structural twin defects, which play a crucial role in determining the location and orientation of AF domain walls. The results provide insights into the interplay of crystalline defects, strain, and magnetic ordering in AF materials, offering a route to optimize device performance.

NATURE COMMUNICATIONS (2022)

Article Environmental Sciences

Surface solvation of Martian salt analogues at low relative humidities

Xiangrui Kong et al.

Summary: Salt aerosols play important roles in atmospheric chemistry and climate systems. This study used ambient pressure X-ray photoelectron spectroscopy to characterize Martian salt analogues and their responses to varying relative humidities. The results showed that the surface chemical environment of the salts is similar to ion chromatography results, but differences exist for species that preferentially partition to the surface or the bulk. The study also found that changes in relative humidity do not have a major impact on the surface chemical environment.

ENVIRONMENTAL SCIENCE-ATMOSPHERES (2022)

Article Chemistry, Physical

The Complex Degradation Mechanism of Copper Electrodes on Lead Halide Perovskites

Sebastian Svanstrom et al.

Summary: This study investigates the interface reactions between lead halide perovskites and copper in solar cells, revealing rich interfacial chemistry and significant degradation of both copper and perovskite over time in the presence of oxygen and moisture.

ACS MATERIALS AU (2022)

Article Instruments & Instrumentation

Transparent top-up injection into a fourth-generation storage ring

Patrick Alexandre et al.

Summary: This paper reports on the design and commissioning of a novel multipole injection kicker (MIK) that successfully reduces the transient stored beam perturbations generated by top-up injection. The MIK demonstrates high injection efficiency and outstanding transparency, with residual disturbances to the stored beam well below the beam size in both the horizontal and vertical planes.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Chemistry, Physical

20.8% Slot-Die Coated MAPbI3 Perovskite Solar Cells by Optimal DMSO-Content and Age of 2-ME Based Precursor Inks

Jinzhao Li et al.

Summary: Efficiency records for solution-processed solar cell devices incorporating metal-halide perovskite semiconductors continue to be broken, with the need for scalable process technology and optimized ink formulations highlighted for large-area prototypes. The study demonstrates the importance of rational insights into ink composition and process control for reproducible manufacturing of MHP-based devices. The addition of a limited amount of DMSO prevents the formation of an intermediate crystalline phase and promotes the formation of the desired perovskite phase, while excess DMSO content negatively impacts thin-film morphology.

ADVANCED ENERGY MATERIALS (2021)

Article Multidisciplinary Sciences

Kinetic proofreading of lipochitooligosaccharides determines signal activation of symbiotic plant receptors

Kira Gysel et al.

Summary: Plants and animals utilize cell surface receptors to sense and interpret environmental signals. A specific class of LCO receptors in legumes has been identified to use kinetic proofreading to activate the receptor and control signaling specificity. This finding highlights the potential for receptor engineering to capture benefits in plant-microbe interactions.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2021)

Article Multidisciplinary Sciences

Stroboscopic operando spectroscopy of the dynamics in heterogeneous catalysis by event-averaging

Jan Knudsen et al.

Summary: This study demonstrates how time-resolved ambient pressure photoelectron spectroscopy can be used to track changes in catalyst structure and gas environment simultaneously. By using cyclic gas pulsing and software-based image recognition, it was found that a metallic surface predominantly covered with CO becomes highly active for a few seconds when the O-2:CO ratio is high enough to lift the CO poisoning effect.

NATURE COMMUNICATIONS (2021)

Article Instruments & Instrumentation

Upgrade of the SPECIES beamline at the MAX IV Laboratory

Esko Kokkonen et al.

Summary: The SPECIES beamline has been transferred to the new 1.5 GeV storage ring at the MAX IV Laboratory, where several improvements have been made to enhance the time-resolution and flux of experiments, as well as improve the resolution and flux of X-ray scattering experiments. The endstations now offer unique capabilities for experiments at low photon energies in the vacuum ultraviolet and soft X-ray range.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

HIPPIE: a new platform for ambient-pressure X-ray photoelectron spectroscopy at the MAX IV Laboratory

Suyun Zhu et al.

Summary: HIPPIE is a soft X-ray beamline on the 3 GeV electron storage ring of the MAX IV Laboratory, equipped with an ambient-pressure X-ray photoelectron spectroscopy instrument for in situ and operando experiments. The endstation offers two sample environments: a catalysis cell and an electrochemical/liquid cell, allowing for a wide range of APXPS experiments.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

Measurement of the coherent beam properties at the CoSAXS beamline

Maik Kahnt et al.

Summary: The CoSAXS beamline at the MAX IV Laboratory is a modern multi-purpose coherent small-angle X-ray scattering instrument, designed to provide intense and optionally coherent illumination for coherent imaging and speckle contrast techniques. Experimental quantification of coherence properties in a SAXS instrument at a fourth-generation synchrotron light source was successfully achieved.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

NanoMAX: the hard X-ray nanoprobe beamline at the MAX IV Laboratory

Ulf Johansson et al.

Summary: NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory, utilizing the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments. This paper presents the beamline optics design in detail, performance figures, and an overview of the surrounding infrastructure and operational diffraction endstation.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

The FEL in the SXL project at MAX IV

Weilun Qin et al.

Summary: This paper presents the design and performance parameters of the FEL in the SXL project at the MAX IV Laboratory, focusing on the operation mode and simulation results in Phase 1, as well as potential upgrades in a second phase of the project.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

Commissioning and operation status of the MAX IV 3 GeV storage ring vacuum system

Marek Grabski et al.

Summary: The 3 GeV electron storage ring of the MAX IV laboratory is coated with non-evaporable getter (NEG) thin film, providing low dynamic outgassing rate and pumping of active gases. The vacuum system performs comparably or better than other similar facilities around the world with traditional designs, with low pressure levels and long electron beam lifetime not limited by residual gas density.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Instruments & Instrumentation

Studies on Transverse Resonance Island Buckets in third and fourth generation synchrotron light sources

David K. Olsson et al.

Summary: Transverse Resonance Island Bucket optics control particle motion using non-linear terms in the equation of motion, resulting in additional stable fixed points in transverse phase-space. These optics have the potential to provide pseudo single-bunch operation, as demonstrated in the 1.5 GeV ring where the beamlines can utilize synchrotron radiation from the island orbit while blocking radiation from the standard orbit.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Optics

Correlative optical photothermal infrared and X-ray fluorescence for chemical imaging of trace elements and relevant molecular structures directly in neurons

Nadja Gustavsson et al.

Summary: Alzheimer's disease is the most common cause of dementia, costing about 1% of the global economy. By combining two imaging modalities, structural and chemical information in a single neuron can be assessed directly. The study reveals that in AD-like neurons, iron clusters co-localize with elevated amyloid beta-sheet structures and oxidized lipids.

LIGHT-SCIENCE & APPLICATIONS (2021)

Article Instruments & Instrumentation

Performance and characterization of the FinEstBeAMS beamline at the MAX IV Laboratory

Kirill Chernenko et al.

Summary: FinEstBeAMS is a multidisciplinary beamline constructed at the 1.5 GeV storage ring of the MAX IV synchrotron facility in Lund, Sweden, covering an extremely wide photon energy range using a single elliptically polarizing undulator and grazing-incidence plane grating monochromator. The beamline operation relies on the use of filters to remove higher-order components from the monochromated radiation below 70 eV.

JOURNAL OF SYNCHROTRON RADIATION (2021)

Article Chemistry, Multidisciplinary

Size-induced amorphous structure in tungsten oxide nanoparticles

Mikkel Juelsholt et al.

Summary: The properties of functional materials are closely related to their atomic structure, especially when the materials are at the nanoscale. By systematically investigating the atomic structure of tungsten oxide nanoparticles, it was found that particles smaller than 5 nm exhibit an amorphous structure while larger particles form nanocrystalline rods. Controlling the concentration of the precursors allows for the tuning of nanoparticle size and structure.

NANOSCALE (2021)

Article Instruments & Instrumentation

BioMAX - the first macromolecular crystallography beamline at MAX IV Laboratory

Thomas Ursby et al.

JOURNAL OF SYNCHROTRON RADIATION (2020)

Article Spectroscopy

Future development plans for the MAX IV light source: Pushing further towards higher brightness and coherence

Pedro Fernandes Tavares et al.

JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA (2018)

Review Instruments & Instrumentation

The saga of MAX IV, the first multi-bend achromat synchrotron light source

Nils Martensson et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2018)

Article Instruments & Instrumentation

Pushing the MAX IV 3 GeV storage ring brightness and coherence towards the limit of its magnetic lattice

S. C. Leemann et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2018)

Article Instruments & Instrumentation

FemtoMAX - an X-ray beamline for structural dynamics at the short-pulse facility of MAX IV

Henrik Enquist et al.

JOURNAL OF SYNCHROTRON RADIATION (2018)

Article Materials Science, Multidisciplinary

Soft/MAX - A new Soft X-ray Microscopy and Coherent Imaging Beamline at the MAX IV Facility.

Jorg Schwenke et al.

MICROSCOPY AND MICROANALYSIS (2018)

Article Materials Science, Multidisciplinary

Optics and Coherence at the Soft/MAX Beamline

Karina Thanell et al.

MICROSCOPY AND MICROANALYSIS (2018)

Article Instruments & Instrumentation

Commissioning and first-year operational results ofthe MAXIV 3GeV ring

Pedro F. Tavares et al.

JOURNAL OF SYNCHROTRON RADIATION (2018)

Proceedings Paper Physics, Applied

The BALDER Beamline at the MAX IV Laboratory

K. Klementiev et al.

16TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS16) (2016)

Article Instruments & Instrumentation

The MAX IV storage ring project

Pedro F. Tavares et al.

JOURNAL OF SYNCHROTRON RADIATION (2014)

Article Instruments & Instrumentation

Magnet design for a low-emittance storage ring

Martin Johansson et al.

JOURNAL OF SYNCHROTRON RADIATION (2014)

Article Instruments & Instrumentation

Diffraction-limited storage-ring vacuum technology

Eshraq Al-Dmour et al.

JOURNAL OF SYNCHROTRON RADIATION (2014)