4.6 Article

Glucose diagnosis system combining machine learning and NIR photoacoustic multispectral using a low power CW laser

Journal

BIOMEDICAL OPTICS EXPRESS
Volume 14, Issue 4, Pages 1685-1702

Publisher

Optica Publishing Group
DOI: 10.1364/BOE.485296

Keywords

-

Ask authors/readers for more resources

Non-invasive, portable, and economical dynamic blood glucose monitoring device is essential for diabetes patients. A photoacoustic multispectral near-infrared diagnosis system was used to excite glucose in aqueous solutions and analyze it using a photoacoustic cell. The system was able to predict glucose concentration through various wavelengths.
Non-invasive, portable, economical, dynamic blood glucose monitoring device has become a functional requirement for diabetes in his regulating entire life. In a photoacoustic (PA) multispectral near-infrared diagnosis system, the glucose in aqueous solutions was excited by low power (order of milliwatts) CW laser whose wavelengths were from 1500 to 1630 nm. The glucose in aqueous solutions to be analyzed was contained within the photoacoustic cell (PAC). The PA multispectral signals were measured using a piezoelectric detector, and then the voltage signals from the piezoelectric detector were amplified with a precision Lock-in Amplifier (MFLI500K). The continuously tunable lasers were used to verify the various influencing factors of the PA signal, and the PA spectrum of the glucose solution was examined. Subsequently, six wavelengths with high power were selected at approximately equal intervals from 1500 to 1630 nm, and the gaussian process regression of the quadratic rational kernel was used to collect data through these wavelengths to predict the glucose concentration. The experimental results showed that the near-infrared PA multispectral diagnosis system could be engineered for the prediction of the glucose level (more than 92%, zone A of Clarke Error Grid). Subsequently, the model trained with glucose solution was used to predict serum glucose. With the increase of serum glucose content, the prediction results of the model also showed a high linear relationship, indicating that the photoacoustic method was sensitive to the detection of glucose concentration changes. The results of our study have the potential to not only better develop the PA blood glucose meter but also extend the viability into the detection of otherwise blood components. (c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available