4.2 Article

Direct sac puncture versus transarterial embolization of type II endoleaks after endovascular abdominal aortic aneurysm repair: Comparison of outcomes

Journal

VASCULAR
Volume -, Issue -, Pages -

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/17085381231156661

Keywords

EVAR; Type 2 endoleak; direct sac puncture embolization

Ask authors/readers for more resources

This study compared the efficacy and safety of direct sac puncture (DSP) and transarterial embolization for type 2 endoleaks (T2ELs). The results showed that DSP had a higher success rate and was more effective in achieving aneurysm sac stability and resolution of endoleak compared to transarterial embolization.
Purpose Type 2 endoleak (T2EL) is the most common type of endoleak after endovascular abdominal aortic aneurysm repair (EVAR), and increases the risk of aneurysm sac rupture if it persists beyond 6 months. The purpose of this study is to compare the efficacy and safety of direct sac puncture versus transarterial embolization of T2ELs. Methods Retrospective review of 42 consecutive T2EL embolization procedures, 19 by DSP and 23 by transarterial technique, between January 2015 and December 2020. Primary outcome was aneurysm sac stability and resolution of endoleak at follow-up imaging. Adverse events (AE) were classified based on the Society of Interventional Radiology (SIR) practice guidelines. Results Technical success was 94.7% (18/19) in the DSP group and 86.9% (20/23) in the transarterial group (p = 0.32 (-0.77-0.25)). Treatment efficacy was evaluated in 16 patients in the DSP group and 18 patients in the transarterial group who had follow-up imaging >= 6 months after embolization. Mean imaging follow-up was 17.1 +/- 11.2 (range, 6-41) months in the DSP group and 26.5 +/- 15.4 (range, 6-48) months in the transarterial group (p = 0.06, -19.24-0.37). Treatment efficacy was 75% (12/16) in the DSP group and 33.3% (6/18) in the transarterial group (p = 0.02, 95% CI, 0.09-0.97). There was no procedure-related mortality. Moderate-severe AE occurred in 15.7% (3/19) in the DSP group and 8.7% (2/23) in the transarterial group (p = 0.44, -0.12-0.26). Conclusion In this study, DSP embolization of T2EL was equally safe and more effective than transarterial embolization in achieving aneurysm sac stability and resolution of endoleak.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available