4.7 Article

Optimization and validation of a protein phosphatase inhibition assay for accessible microcystin detection

Journal

TALANTA
Volume 255, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2022.124174

Keywords

Microcystins; Protein phosphatase inhibition assay; PP1; Cyanotoxins; Biosensors; MC-LR

Ask authors/readers for more resources

In this work, we implemented and validated a sensitive phosphatase inhibition assay (PPIA) for the detection of microcystins (MCs) in freshwater. By optimizing the expression and lyophilization of PP1, as well as the assay conditions, we demonstrated the feasibility of this method in algal bloom samples from Argentina. Our findings suggest that PPIA is an effective and accessible alternative to available commercial tests.
The presence of cyanobacterial toxins in freshwater constitutes an increasing public health concern, especially affecting developing countries where the high cost of available methods makes monitoring programs difficult. The phosphatase inhibition assay (PPIA) is a sensitive method with low instrument requirements that allows the quantification of the most frequent cyanotoxins, microcystins (MCs). In this work, we implemented a PPIA, starting from Protein Phosphatase 1 (PP1) expression up to the validation with samples of algal blooms from Argentina. To do this, we optimized the expression and lyophilization of PP1, and the assay conditions. Also, we included robustness and possible interference analysis. We evaluated the most widely used cyanobacterial lysis methods and determined that heating for 15 min at 95 degrees C is simple and adequate for this assay. Then, we performed MC spikes recovery assays on water samples from three dams from Argentina, resulting in a recovery ranging from 77 to 115%. The limit of detection (LOD) was 0.4 mu g/L and the linear range is 0.4 mu g/L -5 mu g/L. Finally, we evaluated 65 environmental samples where MCs was measured by ELISA test containing from 0 mu g/L to 625 mu g/L. The PPIA showed excellent correlation (Pearson correlation coefficient = 0.967), no false negative and no false positives above the 1 mu g/L WHO guideline (0.11 false positive rate). In conclusion, we optimized and validated a PPIA to be an effective and accessible alternative to available commercial tests.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available