4.6 Article

Design of Smartphone-Assisted Point-of-Care Platform for Colorimetric Sensing of Uric Acid via Visible Light-Induced Oxidase-Like Activity of Covalent Organic Framework

Journal

SENSORS
Volume 23, Issue 8, Pages -

Publisher

MDPI
DOI: 10.3390/s23083881

Keywords

covalent organic framework; oxidase-like activity; colorimetric sensing; smartphone platform; uric acid

Ask authors/readers for more resources

In this study, a new two-dimensional TpBpy COF was synthesized and characterized. It exhibited excellent visible light-induced oxidase-like activity and was applied for uric acid detection, showing promising potential for practical application in biological samples.
Monitoring of uric acid (UA) levels in biological samples is of great significance for human health, while the development of a simple and effective method for the precise determination of UA content is still challenging. In the present study, a two-dimensional (2D) imine-linked crystalline pyridine-based covalent organic framework (TpBpy COF) was synthesized using 2,4,6-triformylphloroglucinol (Tp) and [2,2 '-bipyridine]-5,5 '-diamine (Bpy) as precursors via Schiff-base condensation reactions and was characterized with scanning electron microscopy (SEM), Energy dispersive X-ray spectroscopy (EDS), Powder X-ray diffraction (PXRD), Fourier transform infrared (FT-IR) spectroscopy, and Brunauer-Emmett-Teller (BET) assays. The as-synthesized TpBpy COF exhibited excellent visible light-induced oxidase-like activity, ascribed to the generation of superoxide radicals (O-2(center dot-)) by photo-generated electron transfer. TpBpy COF could efficiently oxidase the colorless substrate 3,3 ',5,5 '-tetramethylbenzydine (TMB) into blue oxidized TMB (oxTMB) under visible light irradiation. Based on the color fade of the TpBpy COF + TMB system by UA, a colorimetric procedure was developed for UA determination with a detection limit of 1.7 mu mol L-1. Moreover, a smartphone-based sensing platform was also constructed for instrument-free and on-site detection of UA with a sensitive detection limit of 3.1 mu mol L-1. The developed sensing system was adopted for UA determination in human urine and serum samples with satisfactory recoveries (96.6-107.8%), suggesting the potential practical application of the TpBpy COF-based sensor for UA detection in biological samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available