4.6 Review

A Survey on Current-Mode Interfaces for Bio Signals and Sensors

Related references

Note: Only part of the references are listed.
Article Engineering, Electrical & Electronic

± 0.45 V CMOS Second-Generation Voltage Conveyor Based on Super Source Follower

Abdullah Yesil et al.

Summary: The paper presents a simple ultra-low-voltage realization of second-generation voltage conveyor (VCII) based on the use of super source follower. The proposed VCII has attractive features such as operation under low power supply voltages, compact structure, and capability of operating in a low-voltage environment.

CIRCUITS SYSTEMS AND SIGNAL PROCESSING (2022)

Article Computer Science, Information Systems

New Resistor-Less Electronically Controllable ±C Simulator Employing VCII, DVCC, and a Grounded Capacitor

Giuseppe Ferri et al.

Summary: This paper presents a new realization of an electronically controllable positive and negative floating capacitor multiplier. The proposed topology implements a floating equivalent capacitor between its two input terminals instead of a grounded one. By utilizing the advantages of current conveyor and voltage conveyor, the circuit employs dual-output second-generation voltage conveyor and electronically tunable differential voltage current conveyor as active building blocks. The value of the simulated capacitor is controlled by a control voltage, and the circuit is free from matching conditions. Simulation results demonstrate a wide range of multiplication factor with a low maximum error.

ELECTRONICS (2022)

Article Computer Science, Information Systems

A New Realization of Electronically Tunable Multiple-Input Single-Voltage Output Second-Order LP/BP Filter Using VCII

Leila Safari et al.

Summary: In this paper, a new realization of electronically tunable voltage output second-order low-pass and band-pass filter is proposed. The circuit utilizes an electronically variable second-generation voltage conveyor, which allows for the adjustment of output impedance and tuning of omega(0). This circuit has a simple structure with a reduced number of passive components, and does not require an additional voltage buffer for LP and BP outputs.

ELECTRONICS (2022)

Article Engineering, Electrical & Electronic

Low power class-AB VCII with extended dynamic range

Gianluca Barile et al.

Summary: This paper presents a novel CMOS second generation voltage conveyor (VCII) topology with wide voltage swing at both X and Z terminals. The VCII achieves voltage buffering using a class-AB complementary-MOS closed loop output voltage follower, and simulation results and a comparison table are provided.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2022)

Review Chemistry, Analytical

A Review on VCII Applications in Signal Conditioning for Sensors and Bioelectrical Signals: New Opportunities

Leila Safari et al.

Summary: This study reviews the existing literature on second-generation voltage conveyor (VCII)-based read-out circuits for sensors and bioelectrical signal conditioning. Compared to conventional circuits, the new VCII-based read-out circuits offer simpler circuitry, direct output in voltage form, improved accuracy, gain adjustment using a single grounded resistor, and the potential to connect multiple sensors. The study aims to enhance research in this area and inspire new ideas.

SENSORS (2022)

Proceedings Paper Chemistry, Analytical

Olfactory Bulb Biosensor Monitoring the Effect of Treatment Drugs for AD in vitro

Mengxue Liu et al.

Summary: Alzheimer's disease is a severe neurodegenerative disease with limited treatment options. However, intranasal drug administration, due to its proximity to the brain, provides a promising avenue for Alzheimer's disease treatment. Olfactory dysfunction is an early symptom of Alzheimer's disease, and a biosensor based on Microelectrode Array technology can be used to monitor the effect of Alzheimer's disease drugs in real-time, offering potential for individualized treatment.

2022 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2022) (2022)

Article Computer Science, Hardware & Architecture

Noise analysis and optimization of VCII-based SiPM interface circuit

G. Ferri et al.

Summary: Recently, second generation voltage conveyor (VCII)-based transimpedance amplifiers (TIAs) have gained popularity in various applications, particularly in silicon photomultiplier (SiPMs) interfacing circuitry, due to their advantages such as low impedance, fast response, high bandwidth, and low power consumption. This study focuses on noise specifications and optimization of VCII-based SiPM interface circuits, introducing a noise model of VCII and discussing methods to optimize trade-offs between key parameters including power consumption, gain, and noise performance. Simulation results show a significant reduction in noise performance by two orders of magnitude compared to previous work, while maintaining other performance parameters.

ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING (2021)

Article Chemistry, Analytical

A Second-Generation Voltage-Conveyor-Based Interface for Ultrasonic PVDF Sensors

Salvatore A. Pullano et al.

Summary: The study introduces a novel approach for receiving ultrasounds in air using a piezopolymer sensor and VCII electronic interface, achieving a sensitivity level of about -100 dB without any filtration stage. The results are obtained using a commercially available AD844 for the second-generation voltage conveyor active device with a supply voltage of +/- 15 V.

MICROMACHINES (2021)

Article Computer Science, Hardware & Architecture

A New Voltage Mode KHN Biquad Using VCII

Sanuj Kulshrestha et al.

Summary: This paper proposes a new voltage mode biquad based on the second generation voltage conveyor (VCII), which is equivalent to the KHN biquadratic circuit. The circuit efficiently adds and subtracts voltages by exploiting virtual ground at one terminal of the VCII, while maintaining the independent tuning of quality factor and characteristic frequency for the filters. The viability of the proposed circuit has been confirmed through LTspice simulations, and the paper also presents the analysis of nonideal characteristics, sensitivity, distortion, linearity, and Monte Carlo analysis for the filters of the proposed circuit.

JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS (2021)

Review Chemistry, Analytical

A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors

Varnakavi Naresh et al.

Summary: Biosensors are receptor-transducer devices that convert biological responses into electrical signals, which have gained significant attention from researchers and scientists in the past decade due to their wide applications in various fields. The main challenges in biosensor development include efficient capture of biorecognition signals, enhancing transducer performance, and miniaturization of biosensing devices, which can be addressed through the integration of sensing technology with nanomaterials.

SENSORS (2021)

Article Engineering, Electrical & Electronic

A new VCII based grounded positive/negative capacitance multiplier

V Stornelli et al.

Summary: This paper proposes a grounded capacitance multiplier based on VCII, which can produce positive and negative voltage multiplication factors. The circuit features high resolution, low power consumption, and a simple structure, and has been verified through SPICE simulation and experimental testing.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2021)

Article Computer Science, Information Systems

Electronically Tunable First Order AP/LP and LP/HP Filter Topologies Using Electronically Controllable Second Generation Voltage Conveyor (CVCII)

Gianluca Barile et al.

Summary: Two new first order filter topologies using electronically controllable second generation voltage conveyors (CVCIIs) are presented in this paper. The first one achieves V-LP/I-AP/V-AP outputs, while the second one achieves I-LP/V-LP/I-HP/V-HP outputs.

ELECTRONICS (2021)

Article Computer Science, Information Systems

Towards Realization of a Low-Voltage Class-AB VCII with High Current Drive Capability

Leila Safari et al.

Summary: This paper presents the implementation of a low-voltage class AB second generation voltage conveyor (VCII) with high current drive capability, featuring simple realization and good overall performance. Proper solutions and techniques were used to achieve high signal swing and high linearity at Y, X and Z ports of VCII as well as low-voltage operation. The operation of the proposed VCII was verified through SPICE simulations, showing good performance at different ports.

ELECTRONICS (2021)

Article Engineering, Electrical & Electronic

A New VCII Application: Sinusoidal Oscillators

Vincenzo Stornelli et al.

Summary: This paper aims to prove the feasibility of implementing sinusoidal oscillators based on second-generation voltage conveyor (VCII) through a canonic approach. The results show that a pair of new canonic oscillators based on negative type VCII can be achieved, while no canonic oscillator configuration is possible using positive type VCII. The analysis demonstrates that the presented oscillator configurations for 5-node networks are the only possible ones and utilize two resistors, two capacitors, and a single VCII-.

JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS (2021)

Article Computer Science, Information Systems

A Novel General Purpose Combined DFVF/VCII Based Biomedical Amplifier

Vincenzo Stornelli et al.

ELECTRONICS (2020)

Article Engineering, Electrical & Electronic

Ultra low-power electronically tunable current-mode instrumentation amplifier for biomedical applications

Costas Psychalinos et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2020)

Article Engineering, Electrical & Electronic

A new versatile full wave rectifier using voltage conveyors

L. Safari et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2020)

Article Engineering, Electrical & Electronic

Full-Analog Parasitic Capacitance Compensation for AC-Excited Differential Sensors

Emiliano Sisinni et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2020)

Article Engineering, Electrical & Electronic

A Closed-Loop Capacitance-to-Frequency Converter for Single-Element and Differential Capacitive Sensors

Lakshmi Areekath et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2020)

Review Biochemistry & Molecular Biology

Cholesterol biosensors: A review

Vinay Narwal et al.

STEROIDS (2019)

Article Engineering, Electrical & Electronic

Fabrication and Validation of a Handheld Non-Invasive, Optical Biosensor for Self-Monitoring of Glucose Using Saliva

Amit Kumar Singh et al.

IEEE SENSORS JOURNAL (2019)

Article Chemistry, Analytical

A VCII-Based Stray Insensitive Analog Interface for Differential Capacitance Sensors

Gianluca Barile et al.

SENSORS (2019)

Article Engineering, Electrical & Electronic

Traditional Op-Amp and new VCII: A comparison on analog circuits applications

Leila Safari et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2019)

Article Computer Science, Information Systems

A New Rail-to-Rail Second Generation Voltage Conveyor

Gianluca Barile et al.

ELECTRONICS (2019)

Proceedings Paper Nuclear Science & Technology

An Analog Front-end ASIC Design for 16-channel SiPM Readout in PET Detectors

Xiaoyu Zhou et al.

2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) (2019)

Proceedings Paper Engineering, Electrical & Electronic

Segmented Digital SiPM

Vikas Vinayaka et al.

2019 IEEE 62ND INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS) (2019)

Article Engineering, Electrical & Electronic

A rail-to-rail constant-gm CCII for Instrumentation Amplifier applications

V Stornelli et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2018)

Article Engineering, Electrical & Electronic

Autobalancing Analog Front End for Full-Range Differential Capacitive Sensing

Alessandro Depari et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2018)

Article Computer Science, Interdisciplinary Applications

High performance voltage output filter realizations using second generation voltage conveyor

Leila Safari et al.

INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING (2018)

Article Chemistry, Analytical

A Novel Electronic Interface for Micromachined Si-Based Photomultipliers

Leonardo Pantoli et al.

MICROMACHINES (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

A SiPM-Readout ASIC for SPECT Applications

Paolo Trigilio et al.

IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES (2018)

Article Engineering, Electrical & Electronic

A CCII-based non-inverting Schmitt trigger and its application as astable multivibrator for capacitive sensor interfacing

Andrea De Marcellis et al.

INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS (2017)

Article Engineering, Electrical & Electronic

Full range analog Wheatstone bridge-based automatic circuit for differential capacitance sensor evaluation

G. Ferri et al.

INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS (2017)

Review Chemistry, Analytical

Capacitive Biosensors and Molecularly Imprinted Electrodes

Gizem Erturk et al.

SENSORS (2017)

Article Engineering, Electrical & Electronic

Current conveyor-based differential capacitance analog interface for displacement sensing application

Giuseppe Ferri et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2017)

Article Engineering, Electrical & Electronic

The AB-CCII, a novel adaptive biasing LV-LP current conveyor architecture

V. Stornelli et al.

AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS (2017)

Article Engineering, Electrical & Electronic

Si Photomultipliers for Bio-Sensing Applications

Maria Francesca Santangelo et al.

IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS (2016)

Article Engineering, Electrical & Electronic

A High Dynamic Range CMOS Readout Chip for Electrochemical Sensors

Min Chen et al.

IEEE SENSORS JOURNAL (2016)

Proceedings Paper Automation & Control Systems

Novel PWM Based Readout Circuit for Pressure Sensors

Jun Long

2016 3RD INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE) (2016)

Article Engineering, Electrical & Electronic

Dynamic and Wireless Sensing Measurements of Potentiometric Glucose Biosensor Based on Graphene and Magnetic Beads

Jung-Chuan Chou et al.

IEEE SENSORS JOURNAL (2015)

Article Engineering, Electrical & Electronic

Uncalibrated operational amplifier-based sensor interface for capacitive/resistive sensor applications

Andrea De Marcellis et al.

IET CIRCUITS DEVICES & SYSTEMS (2015)

Article Engineering, Electrical & Electronic

88-μA 1-MHz Stray-Insensitive CMOS Current-Mode Interface IC for Differential Capacitive Sensors

Giuseppe Scotti et al.

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS (2014)

Article Engineering, Electrical & Electronic

Regulated Common-Gate Transimpedance Amplifier Designed to Operate With a Silicon Photo-Multiplier at the Input

Manuel de Medeiros Silva et al.

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS (2014)

Article Engineering, Electrical & Electronic

Quasi-digital front-ends for current measurement in integrated circuits with giant magnetoresistance technology

Andrea De Marcellis et al.

IET CIRCUITS DEVICES & SYSTEMS (2014)

Article Engineering, Electrical & Electronic

A Magnetic Biosensor System for Detection of E. coli

Fuquan Li et al.

IEEE TRANSACTIONS ON MAGNETICS (2013)

Article Chemistry, Analytical

A CMOS integrated low-voltage low-power time-controlled interface for chemical resistive sensors

A. De Marcellis et al.

SENSORS AND ACTUATORS B-CHEMICAL (2013)

Article Chemistry, Analytical

A novel 6-decades fully-analog uncalibrated Wheatstone bridge-based resistive sensor interface

Andrea De Marcellis et al.

SENSORS AND ACTUATORS B-CHEMICAL (2013)

Article Chemistry, Analytical

Analog Wheatstone bridge-based automatic interface for grounded and floating wide-range resistive sensors

Andrea De Marcellis et al.

SENSORS AND ACTUATORS B-CHEMICAL (2013)

Article Engineering, Electrical & Electronic

Uncalibrated Analog Bridge-Based Interface for Wide-Range Resistive Sensor Estimation

Paolo Mantenuto et al.

IEEE SENSORS JOURNAL (2012)

Article Engineering, Electrical & Electronic

New Acid Biosensor for Taste Transduction Based on Extracellular Recording of PKD Channels

Chunsheng Wu et al.

IEEE SENSORS JOURNAL (2012)

Article Engineering, Electrical & Electronic

A Low Power CMOS Voltage Regulator for a Wireless Blood Pressure Biosensor

Paulo Cesar Crepaldi et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2012)

Article Computer Science, Hardware & Architecture

A CCII-BASED HIGH IMPEDANCE INPUT STAGE FOR BIOMEDICAL APPLICATIONS

Giuseppe Ferri et al.

JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS (2011)

Review Chemistry, Analytical

Glucose Biosensors: An Overview of Use in Clinical Practice

Eun-Hyung Yoo et al.

SENSORS (2010)

Article Engineering, Electrical & Electronic

Current Conveyor-Based Square/Triangular Waveform Generators With Improved Linearity

Dipankar Pal et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2009)

Article Engineering, Electrical & Electronic

Capacitive Sensor for Three-Axis Force Measurements and Its Readout Electronics

Jose Gerardo Vieira da Rocha et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2009)

Article Engineering, Electrical & Electronic

Current-Mode Capacitive Sensor Interface Circuit With Single-Ended to Differential Output Capability

Tajeshwar Singh et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2009)

Article Engineering, Electrical & Electronic

A novel low-voltage low-power fully differential voltage and current gained CCII for floating impedance simulations

Andrea De Marcellis et al.

MICROELECTRONICS JOURNAL (2009)

Article Instruments & Instrumentation

Experimental characterization of the 192 channel Clear-PEM frontend ASIC coupled to a multi-pixel APD readout of LYSO:Ce crystals

Edgar Albuquerque et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2009)

Article Chemistry, Analytical

A single-chip integrated interfacing circuit for wide-range resistive gas sensor arrays

Giuseppe Ferri et al.

SENSORS AND ACTUATORS B-CHEMICAL (2009)

Article Engineering, Electrical & Electronic

Digital Converter for Differential Capacitive Sensors

N. Madhu Mohan et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2008)

Article Engineering, Electrical & Electronic

A CMOS integrable oscillator-based front end for high-dynamic-range resistive sensors

Andrea De Marcellis et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2008)

Article Engineering, Electrical & Electronic

A current-mode, dual slope, integrated capacitance-to-pulse duration converter

Paolo Bruschi et al.

IEEE JOURNAL OF SOLID-STATE CIRCUITS (2007)

Article Engineering, Electrical & Electronic

Switched capacitor signal conditioning for differential capacitive sensors

Boby George et al.

IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT (2007)

Article Engineering, Electrical & Electronic

Novel readout electronics for thickness shear-mode liquid sensors compensating for spurious conductivity and capacitances

Christian Riesch et al.

IEEE SENSORS JOURNAL (2007)

Review Materials Science, Ceramics

Piezoelectric materials for high frequency medical imaging applications: A review

K. K. Shung et al.

JOURNAL OF ELECTROCERAMICS (2007)

Article Physics, Applied

Zinc oxide nanocomb biosensor for glucose detection

J. X. Wang et al.

APPLIED PHYSICS LETTERS (2006)

Article Engineering, Electrical & Electronic

A new topology for a current-mode Wheatstone bridge

YH Ghallab et al.

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS (2006)

Article Engineering, Electrical & Electronic

A current conveyor-based relaxation oscillator as a versatile electronic interface for capacitive and resistive sensors

MT Abuelma'Atti et al.

INTERNATIONAL JOURNAL OF ELECTRONICS (2005)

Article Biophysics

A new quantitative optical biosensor for protein characterisation

GH Cross et al.

BIOSENSORS & BIOELECTRONICS (2003)

Article Engineering, Electrical & Electronic

Current-mode triangular wave generator using CCIIs

B Almashary et al.

MICROELECTRONICS JOURNAL (2000)