4.5 Article

ZnO-6LiF/polystyrene composite scintillator for thermal neutron radiation detection

Journal

REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 94, Issue 2, Pages -

Publisher

AIP Publishing
DOI: 10.1063/5.0126282

Keywords

-

Ask authors/readers for more resources

We prepared a ZnO-6LiF composite using a solution mixing process, with a polystyrene polymer as the host. The composite showed enhanced scintillation pulse heights when compared to pure ZnO or natural LiF. The results demonstrate the potential of the ZnO-6LiF/PS composite for detecting thermal neutron radiation when coupled to a PMT.
We report the preparation of the ZnO-6LiF composite with a polystyrene (PS) polymer as a host using the solution mixing process. 6LiF acts as a converter material that absorbs a thermal neutron and produces alpha particles, which excites ZnO micro-particles, resulting in UV-vis photons' emission. The free-standing ZnO-6LiF/PS composite film is coupled to a photomultiplier tube (PMT). 241Am-Be (1Ci) is used as the neutron radiation source for measuring the response. We compared the response of the composite scintillator consisting of (i) natural LiF and (ii) 95% 6Li enriched LiF (6LiF). The increased pulse heights are recorded for 95% 6Li enriched, i.e., 6LiF converter. It confirms the generation of alpha particles after the absorption of a neutron in 6LiF. Furthermore, ZnO and 6LiF are considered in different weight proportions, 2:1, 1:1, and 1:2, keeping the total loading 50% (w/w) of polystyrene. The ZnO:6LiF (1:1)/PS composite showed higher scintillation pulse heights than the other two composites. Repetitive measurements are performed for the ZnO-6LiF(1:1)/PS composite, showing +/- 5% variation in respective responses. We also investigated the impact of different counting times and source-to-detector responses for the ZnO-6LiF(1:1)/PS composite. The response increases linearly with neutron dose, exhibiting a sensitivity of similar to 203 counts/mu Sv. Neutron measurement counts at different source-to-detector distances have a similar trend as that of neutron dose measured by using a neutron dosimeter. Thus, this work demonstrated the potential of the ZnO-6LiF/PS composite, coupled to PMT for detecting thermal neutron radiation. Published under an exclusive license by AIP Publishing. https://doi.org/10.1063/5.0126282

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available