4.4 Review

Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study

Related references

Note: Only part of the references are listed.
Review Radiology, Nuclear Medicine & Medical Imaging

FLASH radiotherapy with carbon ion beams

Uli Andreas Weber et al.

Summary: FLASH radiotherapy is a potential breakthrough in cancer treatment, utilizing ultra-high dose rates to reduce normal tissue toxicity while maintaining tumor control. There are ongoing clinical trials exploring the use of charged particles such as electrons or protons, with promising outcomes. However, technical challenges remain, particularly in determining the effectiveness of FLASH therapy with heavier ions like carbon.

MEDICAL PHYSICS (2022)

Article Engineering, Biomedical

Roadmap: proton therapy physics and biology

Harald Paganetti et al.

Summary: Proton radiation therapy has become a mainstream treatment option for cancer, with almost 200 000 patients treated worldwide. Despite its advanced dose shaping capabilities, there are still challenges to address, including uncertainties, room for improvement in dose delivery, and biological effect differences compared to photon radiation. Additionally, the economic aspect of proton therapy, with its higher costs compared to conventional treatments, is also an area of active research.

PHYSICS IN MEDICINE AND BIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Prompt-gamma emission in GEANT4 revisited and confronted with experiment

Aleksandra Wronska et al.

Summary: This paper investigates the field of online monitoring of beam range in proton therapy, focusing on the development and simulation of prompt-gamma radiation modalities. By comparing GEANT4 simulations with experimental data, the study identifies the best agreement between measurements and simulations, and concludes that modifications to prompt-gamma emission modeling in higher software versions increase the discrepancy between simulation results and experimental data.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Review Oncology

Carbon Ion Therapy: A Modern Review of an Emerging Technology

Timothy D. Malouff et al.

FRONTIERS IN ONCOLOGY (2020)

Article Physics, Multidisciplinary

A Single-Particle Trigger for Time-of-Flight Measurements in Prompt-Gamma Imaging

Paulo Magalhaes Martins et al.

FRONTIERS IN PHYSICS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

The SiFi-CC project - Feasibility study of a scintillation-fiber-based Compton camera for proton therapy monitoring

Jonas Kasper et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Multidisciplinary Sciences

Inter-fractional monitoring of 12C ions treatments: results from a clinical trial at the CNAO facility

M. Fischetti et al.

SCIENTIFIC REPORTS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility

M. Fontana et al.

IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Results from the experimental evaluation of CeBr3 scintillators for 4He prompt gamma spectroscopy

Riccardo Dal Bello et al.

MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Characterization of prompt gamma ray emission for in vivo range verification in particle therapy: A simulation study

Melek Zarifi et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2019)

Article Engineering, Biomedical

Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery

Theresa Werner et al.

PHYSICS IN MEDICINE AND BIOLOGY (2019)

Review Instruments & Instrumentation

Prompt-gamma monitoring in hadrontherapy: A review

J. Krimmer et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2018)

Article Engineering, Biomedical

A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy

Fernando Hueso-Gonzalez et al.

PHYSICS IN MEDICINE AND BIOLOGY (2018)

Article Engineering, Biomedical

3D prompt gamma imaging for proton beam range verification

E. Draeger et al.

PHYSICS IN MEDICINE AND BIOLOGY (2018)

Article Oncology

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Yunhe Xie et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Spectroscopic study of prompt-gamma emission for range verification in proton therapy

Laurent Kelleter et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy

Maria Giuseppina Bisogni et al.

JOURNAL OF MEDICAL IMAGING (2017)

Article Instruments & Instrumentation

On- and off-line monitoring of ion beam treatment

Katia Parodi

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2016)

Article Oncology

First clinical application of a prompt gamma based in vivo proton range verification system

Christian Richter et al.

RADIOTHERAPY AND ONCOLOGY (2016)

Article Oncology

The FLUKA Code: An Accurate Simulation Tool For Particle Therapy

Giuseppe Battistoni et al.

FRONTIERS IN ONCOLOGY (2016)

Article Nuclear Science & Technology

Overview of the FLUKA code

Giuseppe Battistoni et al.

ANNALS OF NUCLEAR ENERGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Technical Note: Experimental carbon ion range verification in inhomogeneous phantoms using prompt gammas

M. Pinto et al.

MEDICAL PHYSICS (2015)

Article Engineering, Biomedical

Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation

M. Priegnitz et al.

PHYSICS IN MEDICINE AND BIOLOGY (2015)

Article Engineering, Biomedical

Proton range verification through prompt gamma-ray spectroscopy

Joost M. Verburg et al.

PHYSICS IN MEDICINE AND BIOLOGY (2014)

Article Engineering, Biomedical

Range assessment in particle therapy based on prompt γ-ray timing measurements

Christian Golnik et al.

PHYSICS IN MEDICINE AND BIOLOGY (2014)

Article Engineering, Biomedical

Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera

F. Roellinghoff et al.

PHYSICS IN MEDICINE AND BIOLOGY (2014)

Article Engineering, Biomedical

Prompt gamma imaging of proton pencil beams at clinical dose rate

I. Perali et al.

PHYSICS IN MEDICINE AND BIOLOGY (2014)

Review Engineering, Biomedical

In vivo proton range verification: a review

Antje-Christin Knopf et al.

PHYSICS IN MEDICINE AND BIOLOGY (2013)

Article Engineering, Biomedical

Simulation of prompt gamma-ray emission during proton radiotherapy

Joost M. Verburg et al.

PHYSICS IN MEDICINE AND BIOLOGY (2012)

Article Engineering, Biomedical

Range uncertainties in proton therapy and the role of Monte Carlo simulations

Harald Paganetti

PHYSICS IN MEDICINE AND BIOLOGY (2012)

Article Physics, Multidisciplinary

The status of CNAO

S. Rossi

EUROPEAN PHYSICAL JOURNAL PLUS (2011)

Article Instruments & Instrumentation

SRIM - The stopping and range of ions in matter (2010)

James F. Ziegler et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS (2010)

Article Physics, Applied

Prompt gamma measurements for locating the dose falloff region in the proton therapy

Chul-Hee Min et al.

APPLIED PHYSICS LETTERS (2006)

Article Instruments & Instrumentation

Charged hadron tumour therapy monitoring by means of PET

W Enghardt et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2004)