Simplified calculation of peritoneal dialysis-associated peritonitis rate: Accuracy of a recently developed estimating equation

Journal

PERITONEAL DIALYSIS INTERNATIONAL
Volume -, Issue -, Pages -

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/08968608231154156

Keywords

Australia and New Zealand Dialysis and Transplant Registry (ANZDATA); Le Registre de Dialyse Peritoneale de Langue Francaise et Hemodialyse A Domicile (RDPLF); peritoneal dialysis; peritonitis

Ask authors/readers for more resources

In this study, a simple method for estimating the peritonitis rate in peritoneal dialysis (PD) was validated and found to have good agreement with gold-standard measurements in two large dialysis registries. However, the International Society of Peritoneal Dialysis (ISPD) hesitated to recommend its adoption due to concerns about potential inaccuracies. Further analysis of the data sets confirmed the accuracy of the estimating equation and showed that its use would not compromise clinical decision-making for most patients.
Recently, we validated a simple method for estimating peritoneal dialysis (PD) peritonitis rate. Despite good agreement between estimates and gold-standard measurements in two large dialysis registries, the International Society of Peritoneal Dialysis (ISPD) was hesitant to recommend adoption of the estimating equation. Their perception is that inaccuracies, as small as they are, might still be detrimental to clinical decision-making. In this study, we apply new analyses to the original validation data sets. We quantify agreement using standards from the International Organization for Standardization (ISO). We also identify a subset of centres with poorest performance of the estimating equation and qualitatively assess the potential for compromised clinical decision-making associated with its use. Inter-assay % coefficient of variation between estimates and measurements was 4.2% in the Australia and New Zealand Dialysis and Transplant Registry and 4.6% in Le Registre de Dialyse Peritoneale de Langue Francaise, easily meeting ISO requirements. Mandel's h values and Grubb's tests confirmed more outlying estimates compared to the measurements, while Mandel's k values and Cochran's C tests showed that identical precision by the two methods. Misclassification of centres as being above versus below the ISPD standard of 0.4 episodes/patient-year occurred only with rates close to the threshold, affecting approximately 3% of patient-years. In the 26 (out of 268) centres with poorest performance of the estimating equation, examination of the time series of their annual PD peritonitis rate estimates/measurements showed that using estimates would not detrimental to clinical decision-making. In conclusion, the estimating equation is sufficiently accurate for routine clinical use.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available