4.1 Article

Outcomes of transvenous lead extraction in octogenarians using bidirectional rotational mechanical sheaths

Journal

Publisher

WILEY
DOI: 10.1111/pace.14696

Keywords

cardiovascular implantable electronic device; evolution RL rotational sheaths; infection; mortality; transvenous lead extraction

Ask authors/readers for more resources

This study aimed to evaluate the safety and effectiveness of transvenous lead extraction (TLE) in octogenarians with a long lead dwell time. The results showed that the use of bidirectional rotational mechanical sheaths (Evolution RL) had a high success rate of 93.9%. However, the study also found that both 30-day and mid-term mortality rates were still high, especially in the presence of specific comorbidities.
BackgroundOutcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE. MethodsThe study population comprised 83 patients (78.3% male; mean age 85 +/- 3 years; [range 80-94 years]) with 181 target leads. All the leads (mean implant duration 112 +/- 77 months [range 12-377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA). ResultsThe main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty-day mortality after TLE was 6%. During a mean time follow-up of 22 +/- 21 months, 24 patients (29%) died. No procedure-related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87-10.13; p = .001), left ventricularejection fraction <= 35% (HR 7.89; 95% CI 3.20-19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69-10.66; p = .002). ConclusionsAt experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30-day and mid-term mortality are significant, especially in the present of specific comorbidities.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available