4.6 Article

Procedure for determining the number of thermal diffusion columns in square cascade for separation of Ne stable isotopes

Journal

NUCLEAR SCIENCE AND TECHNIQUES
Volume 34, Issue 5, Pages -

Publisher

SPRINGER SINGAPORE PTE LTD
DOI: 10.1007/s41365-023-01217-z

Keywords

Stable isotope; Thermal diffusion; Cascade; Separation; Neon

Ask authors/readers for more resources

The thermal diffusion column is a method for separating stable isotopes, which is suitable for small-scale operations. In this study, the R cascade was used to design and determine the number of columns, and a square cascade was adopted for the final design. The results showed that a cascade of 85 columns is recommended to separate the stable Ne isotopes.
The thermal diffusion column represents one method of separating stable isotopes. This method is advantageous for small-scale operations because of the simplicity of the apparatus and small inventory, especially in gas-phase operations. Consequently, it has attracted attention for its applicability in tritium and noble gas separation systems. In this study, the R cascade was used to design and determine the number of columns. A square cascade was adopted for the final design because of its flexibility, and calculations were performed to separate Ne-20 and Ne-22 isotopes. All the R cascades that enriched the Ne isotopes by more than 99% were investigated, the number of columns was determined, and the square cascade parameters were optimized using the specified columns. Additionally, a calculation code RSQ_CASCADE was developed. A unit separation factor of three was considered, and the number of studied stages ranged from 10 to 20. The results showed that the column separation power, relative total flow rate, and required number of columns were linearly related to the number of stages. The separation power and relative total flow decreased and the number of columns increased as the stage number increased. Therefore, a cascade of 85 columns is recommended to separate the stable Ne isotopes. These calculations yielded a 17-stage square cascade with five columns in each stage. By changing the stage cut, feed point, and cascade feed flow rate, the best parameters for the square cascade were determined according to the cascade and column separation powers. As the column separation power had a maximum value in cascade feed 50, it was selected for separating Ne isotopes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available