4.1 Article

Optimising cylinder model dimensions for VARSKIN to simulate a droplet of radionuclide skin contamination using Geant4 Monte Carlo code

Journal

NUCLEAR MEDICINE COMMUNICATIONS
Volume 44, Issue 5, Pages 366-374

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MNM.0000000000001678

Keywords

contamination; droplet; Geant4; skin dose; VARSKIN

Ask authors/readers for more resources

This study compares the cylindrical geometries available in VARSKIN to more realistic droplet models obtained from photography using the Geant4 Monte Carlo code. The results suggest that different droplet volumes require different cylinder aspect ratios to approximate the true droplet shape. Using the recommended cylinder dimensions in VARSKIN, dose rates from radioactive skin contamination are expected to be within +/- 7.4% of a 'true' droplet model at 95% CI.
Aim VARSKIN provides a convenient way of calculating skin dose from predefined geometries but the models are limited to concentric shapes such as discs, cylinders and point sources. The aim of this article is to use the Geant4 Monte Carlo code to independently compare the cylindrical geometries available in VARSKIN to more realistic droplet models obtained from photography. It may then be possible to recommend an appropriate cylinder model that can be used to represent a droplet within acceptable accuracy. Method Geant4 Monte Carlo code was used to model various droplets of radioactive liquid on the skin based on photographs. The dose rates were then calculated to the sensitive basal layer 70 mu m beneath the surface for three droplet volumes (10, 30 and 50 mu l) and 26 radionuclides. The dose rates from the cylinder models were then compared against the dose rates from the `true' droplet models. Results The table gives the optimum cylinder dimensions that best approximate a true droplet shape for each volume. The mean bias and 95% confidence interval (CI) from the true droplet model are also quoted. Conclusion The evidence from the Monte Carlo data suggests that different droplet volumes require different cylinder aspect ratios to approximate the true droplet shape. Using the cylinder dimensions in the table in software packages such as VARSKIN, dose rates from radioactive skin contamination are expected to be within +/- 7.4% of a 'true' droplet model at 95% CI. Copyright (c) 2023 Wolters Kluwer Health, Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available