4.6 Article

Resazurin Reduction-Based Assays Revisited: Guidelines for Accurate Reporting of Relative Differences on Metabolic Status

Journal

MOLECULES
Volume 28, Issue 5, Pages -

Publisher

MDPI
DOI: 10.3390/molecules28052283

Keywords

resazurin; cell viability; metabolic activity; fluorometric assay; UV-Vis assay; cytotoxicity

Ask authors/readers for more resources

Cell viability and metabolic activity are important parameters in biochemical and biotechnological studies, and resazurin reduction is a commonly used method to assess cell metabolic activity. However, the fundamentals of the resazurin assay and its limitations are not well understood. This work revisits the basics of metabolic activity assays using resazurin and proposes a reliable approach using low concentrations of resazurin for fluorescence ratio assays.
Cell viability and metabolic activity are ubiquitous parameters used in biochemistry, molecular biology, and biotechnological studies. Virtually all toxicology and pharmacological projects include at some point the evaluation of cell viability and/or metabolic activity. Among the methods used to address cell metabolic activity, resazurin reduction is probably the most common. At variance with resazurin, resorufin is intrinsically fluorescent, which simplifies its detection. Resazurin conversion to resorufin in the presence of cells is used as a reporter of metabolic activity of cells and can be detected by a simple fluorometric assay. UV-Vis absorbance is an alternative technique but is not as sensitive. In contrast to its wide empirical black box use, the chemical and cell biology fundamentals of the resazurin assay are underexplored. Resorufin is further converted to other species, which jeopardizes the linearity of the assays, and the interference of extracellular processes has to be accounted for when quantitative bioassays are aimed at. In this work, we revisit the fundamentals of metabolic activity assays based on the reduction of resazurin. Deviation to linearity both in calibration and kinetics, as well as the existence of competing reactions for resazurin and resorufin and their impact on the outcome of the assay, are addressed. In brief, fluorometric ratio assays using low resazurin concentrations obtained from data collected at short time intervals are proposed to ensure reliable conclusions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available