4.5 Article

Dipolectric antenna for high-field MRI

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Multi-feed, loop-dipole combined dielectric resonator antenna arrays for human brain MRI at 7 T

Daniel Wenz et al.

Summary: This study investigates the use of a multi-feed, loop-dipole combined approach to improve the performance of rectangular DRA arrays for MRI at 7 T. Simulations were conducted in a spherical phantom and a human voxel model to analyze different DRA geometries and dielectric constants. The results show that the loop-only feed provides the highest B-1(+) and SAR efficiency, while the loop-dipole configuration achieves the highest SNR in spherical samples. The multi-feed, loop-dipole approach enables the increase of channel number to 24 with 3 channels per block.

MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna

Alireza Sadeghi-Tarakameh et al.

Summary: The study introduces a new antenna element called NODES antenna, which outperforms traditional coil elements in transmit/receive performance, offering higher efficiency and homogeneity. The shortened NODES antenna allows for z-stacked array formation with uniform current distribution.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

A 32-element loop/dipole hybrid array for human head imaging at 7 T

Nikolai I. Avdievich et al.

Summary: A novel hybrid human head array coil was developed to improve whole-brain SNR at 7 Tesla. The coil combined loops and dipoles for improved SNR near the head center and used a hybrid combination of transceive (TxRx) and receive (Rx) elements to minimize the total number of array elements. The developed array significantly improved SNR in vivo and provided higher Tx efficiency and better longitudinal coverage compared to a common commercial array coil.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Biophysics

An 8-dipole transceive and 24-loop receive array for non-human primate head imaging at 10.5 T

Russell L. Lagore et al.

Summary: The 32-channel RF coil was developed for brain imaging of anesthetized non-human primates (rhesus macaque) at 10.5 T, enabling high-resolution anatomical and functional imaging, tractography of axonal bundles, and a threefold reduction in sampling for functional MRI and diffusion MRI. The combination of dipole transceiver array and loop receive array allowed for higher signal-to-noise ratio and parallel imaging gains. The transceive array elements contributed approximately one-quarter of the signal-to-noise ratio in the lower half of the brain, farthest from the close-fitting headcap receive array.

NMR IN BIOMEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved whole-brain SNR with an integrated high-permittivity material in a head array at 7T

Karthik Lakshmanan et al.

Summary: The study demonstrates that strategic use of high-permittivity materials in a helmet design can significantly improve SNR throughout the brain, showing improvements in both transmit efficiency and receive-side SNR. This method is particularly effective in improving SNR at the center of the brain, where other methods may be less effective.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Biophysics

Folded-end dipole transceiver array for human whole-brain imaging at 7 T

Nikolai I. Avdievich et al.

Summary: The study demonstrates that using dipole antennas in designing new RF coils can achieve higher transmission efficiency and better whole-brain coverage, addressing challenges in clinical applications of ultrahigh field MRI.

NMR IN BIOMEDICINE (2021)

Article Physics, Multidisciplinary

Dipole-Fed Rectangular Dielectric Resonator Antennas for Magnetic Resonance Imaging at 7 T: The Impact of Quasi-Transverse Electric Modes on Transmit Field Distribution

Daniel Wenz et al.

Summary: Certain designs of dielectrically shortened dipole antennas can produce an inefficient transmit field when physically separated from the sample, depending on key parameters such as rectangular block geometry, dielectric constant, loading geometry, and RF feeding. Different rectangular block geometries exhibit two main types of quasi-transverse dielectric modes, impacting in vivo MRI experiments involving human body parts. This study provides new insights into dipole antenna design for UHF-MRI, demonstrating how certain antennas maintain their transmit field efficiency despite physical separation from the sample.

FRONTIERS IN PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra-high field MRI

Alireza Sadeghi-Tarakameh et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T

Jeremie D. Clement et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array

Kamil Ugurbil et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

A combined 32-channel receive-loops/8-channel transmit-dipoles coil array for whole-brain MR imaging at 7T

Jeremie Clement et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Approaching ultimate intrinsic specific absorption rate in radiofrequency shimming using high-permittivity materials at 7 Tesla

Gillian G. Haemer et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Modular transmit/receive arrays using very-high permittivity dielectric resonator antennas

Thomas P. A. O'Reilly et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI

M. Arcan Erturk et al.

MAGNETIC RESONANCE IN MEDICINE (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla

Alexander J. E. Raaijmakers et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Power Balance and Loss Mechanism Analysis in RF Transmit Coil Arrays

Andre Kuehne et al.

MAGNETIC RESONANCE IN MEDICINE (2015)

Article Biochemical Research Methods

An eight-channel transmit/receive array of TE01 mode high permittivity ceramic resonators for human imaging at 7 T

S. A. Aussenhofer et al.

JOURNAL OF MAGNETIC RESONANCE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

A 16-Channel Dual-Row Transmit Array in Combination with a 31-Element Receive Array for Human Brain Imaging at 9.4 T

G. Shajan et al.

MAGNETIC RESONANCE IN MEDICINE (2014)

Article Chemistry, Physical

Optimization of the radiative antenna for 7-T magnetic resonance body imaging

Ozlem Ipek et al.

CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitative assessment of the effects of high-permittivity pads in 7 Tesla MRI of the brain

Wouter M. Teeuwisse et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

SA2RAGE: A new sequence for fast B1+-mapping

Florent Eggenschwiler et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Design and evaluation of a detunable water-based quadrature HEM11 mode dielectric resonator as a new type of volume coil for high field MRI

Sebastian A. Aussenhofer et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Design of a Radiative Surface Coil Array Element at 7 T: The Single-Side Adapted Dipole Antenna

A. J. E. Raaijmakers et al.

MAGNETIC RESONANCE IN MEDICINE (2011)

Article Biochemical Research Methods

New high dielectric constant materials for tailoring the B1+ distribution at high magnetic fields

K. Haines et al.

JOURNAL OF MAGNETIC RESONANCE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

96-Channel Receive-Only Head Coil for 3 Tesla: Design Optimization and Evaluation

Graham C. Wiggins et al.

MAGNETIC RESONANCE IN MEDICINE (2009)

Article Chemistry, Physical

An eight-channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T

Cornelius Von Morze et al.

CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Image reconstruction in SNR units: A general method for SNR measurement

P Kellman et al.

MAGNETIC RESONANCE IN MEDICINE (2005)