SuperDyna is a fusion imaging method that combines high-resolution CBCT and contrasted 3D-DSA to evaluate intracranial vasculature post-treatment. It allows for more comprehensive evaluation of the device position and apposition, aiding in treatment planning and patient education.
Background Current imaging algorithms for post-device evaluation are limited by either poor representation of the device or poor delineation of the treated vessel. Combining the high-resolution images from a traditional three-dimensional digital subtraction angiography (3D-DSA) protocol with the longer cone-beam computed tomography (CBCT) protocol may provide simultaneous visualization of both the device and the vessel content in a single volume, improving the accuracy and detail of the assessment. We aim here to review our use of this technique which we termed SuperDyna. Methods In this retrospective study, patients who underwent an endovascular procedure between February 2022 and January 2023 were identified. We analyzed patients who had both non-contrast CBCT and 3D-DSA post-treatment and collected information on pre-/post-blood urea nitrogen, creatinine, radiation dose, and the intervention type. Results In 1 year, SuperDyna was performed in 52 (of 1935, 2.6%) patients, of which 72% were women, median age 60 years. The most common reason for the addition of the SuperDyna was for post-flow diversion assessment (n=39). Renal function tests showed no changes. The average total procedure radiation dose was 2.8 Gy, with 4% dose and similar to 20 mL of contrast attributed to the additional 3D-DSA needed to generate the SuperDyna. Conclusions The SuperDyna is a fusion imaging method that combines high-resolution CBCT and contrasted 3D-DSA to evaluate intracranial vasculature post-treatment. It allows for more comprehensive evaluation of the device position and apposition, aiding in treatment planning and patient education.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available