4.5 Article

Detection of inflow obstruction in left ventricular assist devices by accelerometer: A porcine model study

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Improved Detection Of Thromboembolic Complications In Left Ventricular Assist Device By Novel Accelerometer-Based Analysis

Itai Schalit et al.

Summary: This study aims to improve the diagnosis of thromboembolic complications in HVAD by using vibration analysis. Changes in nonharmonic amplitude (NHA) and the third harmonic amplitude were analyzed to detect thromboembolic events, and combining these two methods improved the positive predictive value.

ASAIO JOURNAL (2022)

Article Engineering, Biomedical

Thrombus formation at the inflow cannula of continuous-flow left ventricular assist devices-A systematic analysis

Friedrich Kaufmann et al.

Summary: In this study, we systematically investigated the impact of cannula surface on thrombus formation in continuous-flow left ventricular assist devices. The results showed that polished cannulas had a higher percentage and length of thrombus formation at the entry site compared to sintered cannulas. A sintered surface is crucial for anchoring myocardial tissue to the cannula.

ARTIFICIAL ORGANS (2022)

Article Engineering, Biomedical

Detection of inflow obstruction in left ventricular assist devices by accelerometer: An in vitro study

Didrik Lilja et al.

Summary: The accelerometer detected LVAD inflow obstructions much better than PLVAD, potentially offering a monitoring modality for any pendulating obstructive inflow pathology in the future.

MEDICAL ENGINEERING & PHYSICS (2022)

Article Cardiac & Cardiovascular Systems

Inflow cannula obstruction of the HeartWare left ventricular assist device: what do we really know?

Federico Pappalardo et al.

Summary: This case report highlights the importance of early recognition of HVAD inflow cannula obstruction leading to in-pump thrombosis and complete cannula occlusion. Effective strategies and tools for the diagnosis and management of this complication are currently lacking.

CARDIOVASCULAR PATHOLOGY (2021)

Article Engineering, Biomedical

Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis

Michael Neidlin et al.

Summary: The study reveals the potential impact of inflow cannulation angles on thrombosis risk, suggesting that ideal inflow cannula alignment is towards the mitral valve and parallel to the septum. However, the optimal approach may vary depending on other patient factors and may change during the course of LVAD support.

BIOMEDICAL ENGINEERING ONLINE (2021)

Article Medicine, General & Internal

Acoustic Properties of Axial and Centrifugal Flow Left Ventricular Assist Devices and Prediction of Pump Thrombosis

Barry A. Boilson et al.

Summary: The study characterized the properties of audible tones produced by approved left ventricular assist device (LVAD) pumps and found that changes in amplitude may be present in cases of pump thrombosis. These amplitude changes could potentially serve as indicators for the onset of pump thrombosis.

MAYO CLINIC PROCEEDINGS (2021)

Editorial Material Cardiac & Cardiovascular Systems

The ever-changing field of mechanical circulatory support: new challenges at the advent of the 'single device era'

Laurens F. Tops et al.

EUROPEAN JOURNAL OF HEART FAILURE (2021)

Article Engineering, Biomedical

The influence of left ventricular assist device inflow cannula position on thrombosis risk

Mojgan Ghodrati et al.

ARTIFICIAL ORGANS (2020)

Article Computer Science, Information Systems

Detecting Suspected Pump Thrombosis in Left Ventricular Assist Devices via Acoustic Analysis

Beren Semiz et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2020)

Article Cardiac & Cardiovascular Systems

Thrombus on the inflow cannula of the HeartWare HVAD: an update

Carolyn H. Glass et al.

CARDIOVASCULAR PATHOLOGY (2019)

Article Medicine, General & Internal

A Fully Magnetically Levitated Left Ventricular Assist Device - Final Report

M. R. Mehra et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Article Engineering, Biomedical

Sound analysis of the magnetically levitated left ventricular assist device HeartMate 3™

Per Sundbom et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2019)

Letter Cardiac & Cardiovascular Systems

Ischemic stroke and subsequent thrombosis within a HeartMate 3 left ventricular assist system: A cautionary tale

Ivan Netuka et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2018)

Letter Cardiac & Cardiovascular Systems

A case of an obstructive inflow thrombus in a HeartMate 3 from the left ventricle into the pump

Jaime-Juergen Eulert-Grehn et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2018)

Article Engineering, Biomedical

Accelerometer Detects Pump Thrombosis and Thromboembolic Events in an In vitro HVAD Circuit

Itai Schalit et al.

ASAIO JOURNAL (2018)

Article Engineering, Biomedical

Echocardiographic outflow pump ramp test in centrifugal-flow left ventricular assist device

Attilio Iacovoni et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2017)

Review Engineering, Biomedical

HVAD Flow Waveform Morphologies: Theoretical Foundation and Implications for Clinical Practice

Jonathan D. Rich et al.

ASAIO JOURNAL (2017)

Letter Cardiac & Cardiovascular Systems

Thrombus around the redesigned HeartWare HVAD inflow cannula: A pathologic case series

Kyle C. Strickland et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2016)

Article Cardiac & Cardiovascular Systems

Diagnosis and Treatment Algorithm for Blood Flow Obstructions in Patients With Left Ventricular Assist Device

Anna Mara Scandroglio et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2016)

Letter Cardiac & Cardiovascular Systems

Cerebral protection system applied during washout of thrombus occluding inflow cannula of HeartWare HVAD left ventricular assist device

Evgenij V. Potapov et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2015)

Meeting Abstract Cardiac & Cardiovascular Systems

The Harmonic Pattern of Ventricular Assist Device Audiosignals: Correlation to Pump Speed and Aortic Valve Opening

D. Bull et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2015)

Article Engineering, Biomedical

Acoustic Analysis of a Mechanical Circulatory Support

Laila Hubbert et al.

ARTIFICIAL ORGANS (2014)

Article Engineering, Biomedical

Acoustic Spectral Analysis for Determining Pump Thrombosis in Rotary Blood Pumps

Friedrich Kaufmann et al.

ASAIO JOURNAL (2014)

Article Cardiac & Cardiovascular Systems

An analysis of pump thrombus events in patients in the Heart Ware ADVANCE bridge to transplant and continued access protocol trial

Samer S. Najjar et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2014)

Article Cardiac & Cardiovascular Systems

Algorithm for the diagnosis and management of suspected pump thrombus

Daniel J. Goldstein et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2013)

Meeting Abstract Cardiac & Cardiovascular Systems

Successful Treatment of Implantable Rotary Left Ventricular Assist Device (LVAD) Thrombus Is Associated with Normalisation of Acoustic Properties

C. T. Bowles et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2011)

Article Cardiac & Cardiovascular Systems

Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models

Kelly H. Zou et al.

CIRCULATION (2007)