4.7 Article

Effect of milk flow rate switch-point settings on cow comfort and milking duration

Journal

JOURNAL OF DAIRY SCIENCE
Volume 106, Issue 4, Pages 2438-2448

Publisher

ELSEVIER SCIENCE INC
DOI: 10.3168/jds.2022-22484

Keywords

milking; cluster removers; cow comfort; milking efficiency

Ask authors/readers for more resources

Automatic cluster removers (ACR) detach the milking unit from the udder once the milk flow has decreased to a predefined level. Increasing the flow rate switch-point is effective in reducing milking duration without impacting milk yield or somatic cell count. This study aimed to measure the effect of different flow rate switch-points on cow comfort, milking duration, and milk yield.
Automatic cluster removers (ACR) operate by ceas-ing vacuum to the cluster and detaching the milking unit from the udder by means of a retracting cord once the milk flow has decreased to a predefined level (i.e., the milk flow rate switch-point). There is a large body of literature on this topic indicating that increasing the flow rate switch-point (e.g., from 0.2 kg/min to 0.8 kg/min at the udder level) is effective in reducing milking duration while having little effect on milk yield or milk somatic cell count (SCC). However, despite these findings many farms still use a switch-point of 0.2 kg/min because it is believed that emptying the udder completely at each milking is a prerequisite for good dairy cow management, especially in relation to maintaining a low milk SCC. However, there may be additional undocumented benefits in terms of cow comfort to increasing the milk flow rate switch-point, because the low milk flow period at the end of milking is a high-risk time for inducing teat-barrel congestion. The objective of this study was to quantify the effect of 4 milk flow rate switch-point settings on cow comfort, milking duration, and milk yield. In this study, we ap-plied 4 treatments consisting of different milk flow rate switch-points to cows in a crossover design in a spring calving grass based dairy herd in Ireland. The treat-ments were (1) MFR0.2, where the cluster was removed at a milk flow rate of 0.2 kg/min; (2) MFR0.4, where the cluster was removed at 0.4 kg/min; (3) MFR0.6, where the cluster was removed at 0.6 kg/min, and (4) MFR0.8, where the cluster was removed at 0.8 kg/ min. Milking parameters were recorded by the parlor software and leg movements (i.e., kicks or steps) during milking were recorded with an accelerometer. These data were used as a proxy for cow comfort during milk-ing. The results of this study showed significant differ-ences in cow comfort across treatments, as indicated by cow stepping during milking, for a.m. milkings, but these differences were not detected for p.m. milkings, possibly because a.m. milkings were longer than p.m. milkings due to a 16:8 h milking interval on the research farm. Differences tended to distinguish the 2 lower-flow switch-point settings with greater leg movement against the 2 higher-flow switch-point settings with less leg movement during milking. The effect of treatment (milk flow rate switch-point) on daily milking duration was significant. The milk duration for MFR0.8 was 89 s (14%) shorter than MFR0.2. There was no significant effect of treatment on SCC in this study.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available