4.2 Article

Implantable defibrillator-detected heart failure status predicts ventricular tachyarrhythmias

Journal

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
Volume 34, Issue 5, Pages 1257-1267

Publisher

WILEY
DOI: 10.1111/jce.15898

Keywords

cardiac resynchronization therapy; heart failure; ICD shock; implantable cardioverter-defibrillation; risk stratification; ventricular arrhythmias

Ask authors/readers for more resources

This study aimed to assess the predictability of defibrillator therapies using the HeartLogic index among heart failure patients. The results showed a significant association between the HeartLogic index and therapy, suggesting it as an independent dynamic predictor.
IntroductionThe prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. MethodsFive hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. ResultsOver a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic >= 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of >= 1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. ConclusionThe HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available