4.7 Article

Energy saving analysis and thermal performance evaluation of a hydrogen-enriched natural gas-fired condensing boiler

Journal

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 48, Issue 50, Pages 19279-19296

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2023.02.027

Keywords

Hydrogen-enriched natural gas; Energy saving; Heat transfer; Condensing boiler; Condenser; Carbon dioxide

Ask authors/readers for more resources

Hydrogen-enriched natural gas (HENG) has attracted attention for its lower pollutant emissions and potential for industrial decarbonization. This study evaluated the energy saving and thermal performance of a condensing boiler burning HENG. Results showed that H2 enrichment increased flame radiation intensity and improved efficiency and heat transfer rate.
Hydrogen-enriched natural gas (HENG) has attracted widespread attention due to its lower pollutant emissions and industrial decarbonization in the past decades. HENG combustion boosts the water content in the flue gas, which is highly favorable for condensing boilers to recover additional latent heat. The energy saving and thermal performance of a condensing boiler burning HENG were evaluated at a constant heat load of 2.8 MW in this study. The variations in combustion products and boiler efficiency were investigated based on the material balance and energy conservation. The heat transfer calculations were employed to evaluate the thermal performance of boiler heating surfaces. The energy re-covery performance of the condenser was assessed via a thermal design method. Results show that H2 enrichment enhances the radiation intensity of the flame due to the incre-mental triatomic gases with higher emissivity in the furnace. The heat absorption ratio increases with H2 enrichment in the radiative heating surface, while it shows a reverse tendency in the convective heating surface. The condensing boiler efficiency based on lower heating value increases from 101.83% to 110.60%, the total heat transfer rate of the condenser increases from 2.77 x 105 W to 4.61 x 105 W, and the total area required de-creases from 46.45 m2 to 42.16 m2, as the H2 enriches from 0 to 100% under the exhaust flue gas temperature of 318 K. Although the amount of recoverable heat in the exhaust flue gas increases considerably after H2 blending, the original condenser with natural gas as the designed fuel could meet the requirements of the heat recovery for HENG without increasing the extra heating surface. When the H2 fraction is enriched from 0 to 100%, CO2 emission intensity drops from 6.05 x 10-8 kg J-1 to 0. This work may offer some theoretical references for the application and generalization of HENG condensing boilers. (c) 2023 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available