Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction

Journal

IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY
Volume 31, Issue 3, Pages 989-1005

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TCST.2022.3207999

Keywords

Ankle dorsiflexion; drop foot; functional electrical stimulation (FES); nonlinear control; sampled-data observer (SDO); ultrasound (US) imaging

Ask authors/readers for more resources

This study investigated the use of ultrasound echogenicity as an indicator of FES-evoked muscle activation and proposed a control framework that integrates ultrasound measurements. The control framework significantly improved the tracking performance of ankle dorsiflexion compared to the traditional control method that relies only on kinematic feedback. The results demonstrated the potential benefits of this control design for people with drop foot and other mobility disorders.
Open- or closed-loop functional electrical stimulation (FES) has been widely investigated to treat drop foot syndrome, which is typically caused by weakness or paralysis of ankle dorsiflexors. However, conventional closed-loop FES control mainly uses kinematic feedback, which does not directly capture time-varying changes in muscle activation. In this study, we explored the use of ultrasound (US) echogenicity as an indicator of FES-evoked muscle activation and hypothesized that including US-derived muscle activation, in addition to kinematic feedback, would improve the closed-loop FES control performance compared to the closed-loop control that relies only on the kinematic feedback. A sampled-data observer (SDO) was derived to continuously estimate FES-evoked muscle activations from low-sampled US echogenicity signals. In addition, a dynamic surface controller (DSC) and a delay compensation (DC) term were incorporated with the SDO, denoted as the US-based DSC-DC, to drive the actual ankle dorsiflexion trajectory to the desired profile. The trajectory tracking error convergence of the closed-loop system was proven to be uniformly ultimately bounded based on the Lyapunov-Krasovskii stability analysis. The US-based DSC-DC controller was validated on five participants with no disabilities to control their ankle dorsiflexion during walking on a treadmill. The US-based DSC-DC controller significantly reduced the root-mean-square error of the ankle joint trajectory tracking by 46.52% +/- 7.99% ( $p<0.001$ ) compared to the traditional DSC-DC controller with only kinematic feedback but no US measurements. The results also verified the disturbance rejection performance of the US-based DSC-DC controller when a plantarflexion disturbance was added. Our control design, for the first time, provides a methodology to integrate US in an FES control framework, which will likely benefit persons with drop foot and those with other mobility disorders.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available