4.7 Article

Performance Enhancement of an Ag-Au Bimetallic SPR Sensor: A Theoretical and Experimental Study

Journal

IEEE SENSORS JOURNAL
Volume 23, Issue 10, Pages 10420-10428

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2023.3265896

Keywords

Bimetallic sensor; Kretschmann configuration; sensitivity; surface plasmon resonance (SPR)

Ask authors/readers for more resources

This study investigated Ag-Au bimetallic surface plasmon resonance (SPR) sensors in the Kretschmann configuration. Ag-based sensors have high sensitivity but poor stability, while the addition of an Au capping layer improves chemical resistance and analyte bonding. Numerical modeling and experiments evaluated sensors with different Ag-Au thickness ratios, showing that the best SPR response was achieved with 45 nm Ag and 5 nm Au. The fabricated Ag-Au sensors were characterized, and the results were compared to single-layer Ag and Au sensors. The sensitivity of the thickness-optimized bimetallic layer was 1.5 times higher than that of the single-layer Au sensor.
Ag-Au bimetallic surface plasmon resonance (SPR) sensors operating in the Kretschmann configuration were investigated by numerical modeling and experiment. While Ag-based sensors have good sensitivity, they suffer from poor stability, and the addition of an Au capping layer offers improved chemical resistance and reliable analyte bonding via thiol-gold interactions. Sensors were evaluated with an Ag-Au combined thickness of 50 nm but different thickness ratios, and SPR reflectivity curves were obtained for 632.8 nm wavelength light incident over a range of angles. Numerical modeling using the transfer matrix method showed the SPR response improving as Au thickness decreased, giving the best results for 45 nm of Ag and 5 nm of Au. Experimental characterization of fabricated Ag-Au bimetallic sensors was carried out with a custom SPR testbed. Performance parameters, including minimum reflectivity, full-width at half-maximum (FWHM), stability, and sensitivity were measured and the results were compared to those of single-layer Ag and Au sensors. A 5 nm Au coating was unable to preserve stable bimetallic sensor performance; however, increasing the Au thickness to 10 nm was sufficient to protect the Ag sensing layer, allowing only a small variation in the minimum reflectivity and FWHM when exposed to analytes for multiple hours. The sensitivity of the single-layer Ag, bimetallic Ag-Au, and Au sensors was measured as 3041%/refractive index unit (RIU), 1817%/RIU, and 1229%/RIU, respectively. The sensitivity of the thickness-optimized bimetallic layer was similar to 1.5x that of the single-layer Au sensor.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available