4.6 Review

Obstetric and neonatal outcomes after natural versus artificial cycle frozen embryo transfer and the role of luteal phase support: a systematic review and meta-analysis

Journal

HUMAN REPRODUCTION UPDATE
Volume 29, Issue 5, Pages 634-654

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/humupd/dmad011

Keywords

frozen-thawed embryo transfer; artificial cycle; natural cycle; safety; hypertensive disorders of pregnancy; birthweight; luteal phase support

Ask authors/readers for more resources

Based on a systematic review and meta-analysis, natural cycle frozen embryo transfer (NC-FET) appears to be associated with a lower risk of adverse obstetric and neonatal outcomes compared to artificial cycle frozen embryo transfer (AC-FET). Furthermore, NC-FET with luteal phase support (LPS) may reduce the risk of preterm birth. Therefore, NC-FET should be the preferred treatment for women undergoing frozen embryo transfer. The use of LPS in NC-FET may decrease the risk of preterm birth, but more research is needed to determine its efficacy and safety.
BACKGROUND The number of frozen embryo transfers (FET) has increased dramatically over the past decade. Based on current evidence, there is no difference in pregnancy rates when natural cycle FET (NC-FET) is compared to artificial cycle FET (AC-FET) in subfertile women. However, NC-FET seems to be associated with lower risk of adverse obstetric and neonatal outcomes compared with AC-FET cycles. Currently, there is no consensus about whether NC-FET needs to be combined with luteal phase support (LPS) or not. The question of how to prepare the endometrium for FET has now gained even more importance and taken the dimension of safety into account as it should not simply be reduced to the basic question of effectiveness. OBJECTIVE AND RATIONALE The objective of this project was to determine whether NC-FET, with or without LPS, decreases the risk of adverse obstetric and neonatal outcomes compared with AC-FET. SEARCH METHODS A systematic review and meta-analysis was carried out. A literature search was performed using the following databases: CINAHL, EMBASE, and MEDLINE from inception to 10 October 2022. Observational studies, including cohort studies, and registries comparing obstetric and neonatal outcomes between singleton pregnancies after NC-FET and those after AC-FET were sought. Risk of bias was assessed using the ROBINS-I tool. The quality of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach. We calculated pooled odds ratios (ORs), pooled risk differences (RDs), pooled adjusted ORs, and prevalence estimates with 95% CI using a random effect model, while heterogeneity was assessed by the I-2. OUTCOMES The conducted search identified 2436 studies, 890 duplicates were removed and 1546 studies were screened. Thirty studies (NC-FET n = 56 445; AC-FET n = 57 231) were included, 19 of which used LPS in NC-FET. Birthweight was lower following NC-FET versus AC-FET (mean difference 26.35 g; 95% CI 11.61-41.08, I-2 = 63%). Furthermore NC-FET compared to AC-FET resulted in a lower risk of large for gestational age (OR 0.88, 95% 0.83-0.94, I-2 = 54%), macrosomia (OR 0.81; 95% CI 0.71-0.93, I-2 = 68%), low birthweight (OR 0.81, 95% CI 0.77-0.85, I-2 = 41%), early pregnancy loss (OR 0.73; 95% CI 0.61-0.86, I-2 = 70%), preterm birth (OR 0.80; 95% CI 0.75-0.85, I-2 = 20%), very preterm birth (OR 0.66, 95% CI 0.53-0.84, I-2 = 0%), hypertensive disorders of pregnancy (OR 0.60, 95% CI 0.50-0.65, I-2 = 61%), pre-eclampsia (OR 0.50; 95% CI 0.42-0.60, I-2 = 44%), placenta previa (OR 0.84, 95% CI 0.73-0.97, I-2 = 0%), and postpartum hemorrhage (OR 0.43; 95% CI 0.38-0.48, I-2 = 53%). Stratified analyses on LPS use in NC-FET suggested that, compared to AC-FET, NC-FET with LPS decreased preterm birth risk, while NC-FET without LPS did not (OR 0.75, 95% CI 0.70-0.81). LPS use did not modify the other outcomes. Heterogeneity varied from low to high, while quality of the evidence was very low to moderate. WIDER IMPLICATIONS This study confirms that NC-FET decreases the risk of adverse obstetric and neonatal outcomes compared with AC-FET. We estimate that for each adverse outcome, use of NC-FET may prevent 4 to 22 cases per 1000 women. Consequently, NC-FET should be the preferred treatment in women with ovulatory cycles undergoing FET. Based on very low quality of evidence, the risk of preterm birth be decreased when LPS is used in NC-FET compared to AC-FET. However, because of many uncertainties-the major being the debate about efficacy of the use of LPS-future research is needed on efficacy and safety of LPS and no recommendation can be made about the use of LPS.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available