4.5 Article

Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques

Journal

EUROPEAN SPINE JOURNAL
Volume 32, Issue 9, Pages 3094-3104

Publisher

SPRINGER
DOI: 10.1007/s00586-023-07710-8

Keywords

Robotic surgery; Scoliosis; Robotic-navigation; Navigation; Pedicle screw

Ask authors/readers for more resources

This study compared the safety and accuracy of cannulated pedicle screw placement using a robotic-navigation technique, O-arm-based navigation technique, or freehand technique. The results showed that both robotic-navigation and O-arm-based navigation techniques can effectively increase the accuracy and safety of pedicle screw insertion compared to the freehand technique.
PurposeTo compare the safety and accuracy of cannulated pedicle screw placement using a robotic-navigation technique, O-arm-based navigation technique, or freehand technique.MethodsThis study analyzed 106 consecutive patients who underwent scoliosis surgery. Thirty-two patients underwent robotic-navigation-assisted pedicle screw insertion (Group 1), 34 patients underwent O-arm-based navigation-guided pedicle screw insertion (Group 2), and 40 patients underwent freehand pedicle screw insertion (Group 3). The primary outcome measure was the accuracy of screw placement. Secondary outcome parameters included operation time, blood loss, radiation exposure, and postoperative stay.ResultsA total of 2035 cannulated pedicle screws were implanted in 106 patients. The accuracy rate of the first pedicle screw placement during operation was significantly greater in Group 1 (94.7%) than in Group 2 (89.2%; P < 0.001). The accuracy rate of pedicle screw placement postoperatively decreased in the order of Group 1 (96.7%) > Group 2 (93.0%) > Group 3 (80.4%; P < 0.01). There were no significant differences in blood loss or postoperative stay among the three groups (P > 0.05). The operation times of Group 1 and Group 2 were significantly longer than that of Group 3 (P < 0.05).ConclusionThe robotic-navigation and O-arm-based navigation techniques effectively increased the accuracy and safety of pedicle screw insertion alternative to the freehand technique in scoliosis surgery. Compared with the O-arm-based navigation technique, the robotic-navigation technique increases the mean operation time, but also increases the accuracy of pedicle screw placement. A three-dimensional scan after insertion of the K-wire may increase the accuracy of pedicle screw placement in the O-arm-based navigation technique.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available