Agreement between cardiac output measurements by pulse wave analysis using the Pressure Recording Analytical Method and transthoracic echocardiography in patients with veno-venous extracorporeal membrane oxygenation therapy An observational method comparison

Journal

EUROPEAN JOURNAL OF ANAESTHESIOLOGY
Volume 40, Issue 6, Pages 436-441

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/EJA.0000000000001828

Keywords

-

Categories

Ask authors/readers for more resources

The study aims to assess the agreement between CO measured by PRAM and CO measured by TTE in adult patients with vvECMO therapy. The results indicate that PRAM-CO and TTE-CO show clinically acceptable agreement in these patients.
BACKGROUNDMeasuring cardiac output (CO) is important in patients treated with veno-venous extracorporeal membrane oxygenation (vvECMO) because vvECMO flow and CO need to be balanced. Uncalibrated pulse wave analysis with the Pressure Recording Analytical Method (PRAM) may be suitable to measure CO in patients with vvECMO therapy.OBJECTIVETo assess the agreement between CO measured by PRAM (PRAM-CO; test method) and CO measured by transthoracic echocardiography (TTE-CO; reference method).DESIGNA prospective observational method comparison study.SETTINGThe ICU of a German university hospital between March and December 2021.PATIENTSThirty one adult patients with respiratory failure requiring vvECMO therapy: 29 of the 31 patients (94%) were treated for COVID-19 related respiratory failure.MAIN OUTCOME MEASURESPRAM-CO and TTE-CO were measured simultaneously at two time points in each patient with at least 20 min between measurements. A radial or femoral arterial catheter-derived blood pressure waveform was used for PRAM-CO measurements. TTE-CO measurements were conducted using the pulsed wave Doppler-derived velocity time integral of the left ventricular outflow tract (LVOT) and the corresponding LVOT diameter. PRAM-CO and TTE-CO were compared using Bland-Altman analysis and the percentage error (PE). We defined a PE of RESULTSMean +/- SD PRAM-CO was 6.86 +/- 1.49 l min(-1) and mean TTE-CO was 6.94 +/- 1.58 l min(-1). The mean of the differences between PRAM-CO and TTE-CO was 0.09 +/- 0.73 l min(-1) with a lower 95% limit of agreement of -1.34 l min(-1) and an upper 95% limit of agreement of 1.51 l min(-1). The PE was 21%.CONCLUSIONSThe agreement between PRAM-CO and TTE-CO is clinically acceptable in adult patients with vvECMO therapy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available