Keywords

Air-conditioning water system; Energy-saving optimization; Artificial immune system; Data-driven; Optimal control

Ask authors/readers for more resources

The air-conditioning water system deviates from its optimum state under partial load, so it is crucial to dynamically adjust the operating parameters of the equipments in the system to maximize energy efficiency. An improved parallel artificial immune system (IPAIS) algorithm is proposed to determine the optimal parameters under different loads. The algorithm is tested using a simulation experiment on an actual air-conditioning water system, and it achieves superior optimization results compared to other algorithms in terms of convergence, robustness, and computational complexity.
As the air-conditioning water system is designed according to the maximum load, the system will deviate from its optimum state while operating under partial load. Therefore, it is critical that the numerous operating param-eters of the various equipments in the system are dynamically adjusted in an effective and timely manner to maximize the operational energy efficiency of the system. To this end, an improved parallel artificial immune system (IPAIS) algorithm is proposed to determine the optimal operating parameters of the system under different loads. Before optimization, the power consumption model is developed using generalized regression neural network (GRNN) combined with mechanism model for each kind of equipment in the system. Afterwards, the optimal control problem is described with the objective of minimizing the total power consumption of all equipments and considering the relevant constraints. Subsequently, the IPAIS is developed to solve the problem by introducing four improvement strategies. Finally, a simulation experiment is conducted using an actual case of an air-conditioning water system. The results show that the developed power consumption model performs well in accuracy, robustness and generalization ability, and the total system energy consumption is reduced by 15.19% after optimization. Meanwhile, the IPAIS is extended to five variants to confirm the functionality and effectiveness of each improved strategy. Furthermore, the optimization performance of IPAIS in the actual system is comprehensively verified and analyzed using an experimental platform. Compared with the comparison al-gorithms, IPAIS is able to achieve superior optimization results and presents significant advantages in conver-gence, robustness and computational complexity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available