A randomized clinical trial comparing three fixed combinations of bimatoprost with timolol in patients with open-angle glaucoma or ocular hypertension

Journal

CURRENT MEDICAL RESEARCH AND OPINION
Volume -, Issue -, Pages -

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/03007995.2023.2197496

Keywords

Glaucoma; ocular hypertension; bimatoprost; timolol; preservative-free; pharmacokinetics

Ask authors/readers for more resources

This study compared the efficacy and safety of two fixed combination, preservative-free eye drops (bimatoprost 0.01% in combination with either timolol 0.1% or 0.5%) in a gel formulation, with bimatoprost 0.03%/timolol 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). The results suggest that the preservative-free ophthalmic formulation of T4030a (bimatoprost 0.01%/timolol 0.1%) can be regarded as a useful tool in the therapeutic management of OAG and OHT.
Objective: To compare the efficacy and safety of two fixed combination, preservative-free eye drops (bimatoprost 0.01% in combination with either timolol 0.1% or 0.5%) in a gel formulation, with bimatoprost 0.03%/timolol 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods: Phase II, randomized, investigator-masked, multicenter, 3-arm parallel group (Eudract No. 2017-002823-46). Eighty-six patients aged >= 18 years with OAG or OHT, with intraocular pressure (IOP) initially controlled for at least 6months by a combination therapy of a dual prostaglandin and timolol or insufficiently controlled by first-line monotherapy were included. Patients were randomized to receive T4030a (bimatoprost 0.01%/timolol 0.1%; N = 29), T4030c (bimatoprost 0.01%/timolol 0.5%; N = 29) or bimatoprost 0.03%/timolol 0.5% (N = 28), administered once daily in the evening for 12 weeks. Primary endpoint was defined as change in IOP from day 1 to week 12 measured at 08:00 (+/- 1 h). Further efficacy, safety and pharmacokinetic endpoints were assessed as secondary outcomes. Results: The mean change in IOP from baseline to week 12 was -9.8 +/- 2.1mmHg for T4030a, -10.1 +/- 2.5mmHg for T4030c and -10.0 +/- 2.8mmHg for bimatoprost 0.03%/timolol 0.5%. All treatments were well tolerated with no safety issues identified in any group. In patients treated with T4030a, the systemic concentration of timolol was significantly lower after 12 weeks than in patients treated with T4030c or bimatoprost 0.03%/timolol0.5%. Conclusions: These study results suggest that the preservative-free ophthalmic formulation of T4030a (bimatoprost 0.01%/timolol 0.1%) can be regarded as a useful tool in the therapeutic management of OAG and OHT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available