4.7 Article

Dynamic characteristic modeling of left ventricular assist devices based on hysteresis effects

Related references

Note: Only part of the references are listed.
Article Mathematics, Applied

Local Bifurcation Analysis of One Parameter in the Greitzer's Model with a General Compressor Characteristic

Naima Meskine et al.

Summary: Based on the Greitzer's simplified model, this article presents an analytical study on the instability phenomena of the operating point using fundamental properties of nonlinear dynamic systems. Furthermore, a general compressor characteristic curve suitable for stationary systems is proposed. The stability conditions of the model parameters are determined using the Routh-Hurwitz theorem. A numerical simulation is conducted to illustrate the theoretical results.

MEDITERRANEAN JOURNAL OF MATHEMATICS (2022)

Article Engineering, Biomedical

Effect of Timings of the Lavare Cycle on the Ventricular Washout in an In Vitro Flow Visualization Setup

Thananya Khienwad et al.

Summary: The Lavare cycle of the Medtronic HeartWare HVAD can improve ventricular washout, especially when speed changes are applied at the correct timing during the cardiac cycle.

ASAIO JOURNAL (2021)

Article Engineering, Biomedical

CFD Assisted Evaluation of In Vitro Experiments on Bearingless Blood Pumps

Pascal Puentener et al.

Summary: The study conducted a comparative analysis of computational fluid dynamics simulations and in vitro hemolysis examinations of a bearingless centrifugal blood pump. Results showed that a double-stage model achieved the highest correlation, with cell destruction mainly occurring in the radial gap of the pump. Modifying design parameters can improve cell compatibility. The study highlights the limitations and benefits of using CFD models in interpreting in vitro test outcomes.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2021)

Article Engineering, Mechanical

Impact of Different Volume Sizes on Dynamic Stability of a Gas Turbine-Fuel Cell Hybrid System

Alessio Abrassi et al.

JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME (2020)

Article Engineering, Aerospace

The role of shaft-speed oscillation on the instability behavior of transonic radial compressor

Hanxuan Zeng et al.

AEROSPACE SCIENCE AND TECHNOLOGY (2020)

Article Computer Science, Interdisciplinary Applications

Biomechanical effects of the working modes of LVADs on the aortic valve: A primary numerical study

Bin Gao et al.

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE (2020)

Article Computer Science, Interdisciplinary Applications

Biomechanical effects of the novel series LVAD on the aortic valve

Bin Gao et al.

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE (2020)

Article Mathematical & Computational Biology

A numerical model applied to the simulation of cardiovascular hemodynamics and operating condition of continuous-flow left ventricular assist device

Hongtao Liu et al.

MATHEMATICAL BIOSCIENCES AND ENGINEERING (2020)

Article Engineering, Biomedical

Hydraulic Characterization of Implantable Rotary Blood Pumps

Stefan Boes et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2019)

Article Engineering, Biomedical

Blood damage in Left Ventricular Assist Devices: Pump thrombosis or system thrombosis?

Matteo Selmi et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2019)

Article Computer Science, Interdisciplinary Applications

Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD

Zengsheng Chen et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2019)

Article Engineering, Biomedical

Flow features and device-induced blood trauma in CF-VADs under a pulsatile blood flow condition: A CFD comparative study

Zengsheng Chen et al.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2018)

Article Engineering, Aerospace

High blade lift generation through short rotor-stator axial spacing in a tiny pump

Han Xu et al.

AEROSPACE SCIENCE AND TECHNOLOGY (2018)

Article Engineering, Biomedical

Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump

Mohammad Amin Rezaienia et al.

ASAIO JOURNAL (2018)

Proceedings Paper Engineering, Aerospace

Unsteady Character and Flow Fields in an Axial Blood Pump under Pulsatile Pressure Boundary Condition

Mengyu Wang et al.

2018 2ND INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES IN DESIGN, MECHANICAL AND AERONAUTICAL ENGINEERING (ATDMAE 2018) (2018)

Article Engineering, Biomedical

In-silico evaluation of left ventricular unloading under varying speed continuous flow left ventricular assist device support

Selim Bozkurt et al.

BIOCYBERNETICS AND BIOMEDICAL ENGINEERING (2017)

Article Cardiac & Cardiovascular Systems

Classification of Unsteady Flow Patterns in a Rotodynamic Blood Pump: Introduction of Non-Dimensional Regime Map

Fangjun Shu et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2015)

Article Engineering, Biomedical

\Analysis of Pressure Head-Flow Loops of Pulsatile Rotodynamic Blood Pumps

Silje E. Jahren et al.

ARTIFICIAL ORGANS (2014)

Article Cardiac & Cardiovascular Systems

Clinical Outcomes After Continuous-Flow Left Ventricular Assist Device A Systematic Review

Colleen K. McIlvennan et al.

CIRCULATION-HEART FAILURE (2014)

Article Engineering, Biomedical

A Novel Interface for Hybrid Mock Circulations to Evaluate Ventricular Assist Devices

Gregor Ochsner et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2013)

Article Biophysics

A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index

Katharine H. Fraser et al.

JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME (2012)

Article Cardiac & Cardiovascular Systems

Pulsatile control of rotary blood pumps: Does the modulation waveform matter?

Tohid Pirbodaghi et al.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2012)

Review Engineering, Biomedical

The use of computational fluid dynamics in the development of ventricular assist devices

Katharine H. Fraser et al.

MEDICAL ENGINEERING & PHYSICS (2011)

Article Engineering, Biomedical

The Importance of dQ/dt on the Flow Field in a Turbodynamic Pump With Pulsatile Flow

Fangjun Shu et al.

ARTIFICIAL ORGANS (2009)

Article Automation & Control Systems

A Dynamical State Space Representation and Performance Analysis of a Feedback-Controlled Rotary Left Ventricular Assist Device

Marwan A. Simaan et al.

IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY (2009)

Article Engineering, Biomedical

Dynamic modeling and identification of an axial flow ventricular assist device

Francesco Moscato et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2009)

Article Engineering, Biomedical

CFD analysis of a mag-lev ventricular assist device for infants and children: Fourth generation design

Amy L. Throckmorton et al.

ASAIO JOURNAL (2008)