4.7 Article

Mechanical buckling assisted formation of 3D conductive composite meso-structure for highly sensitive piezoresistive pressure sensor

Journal

COMPOSITE STRUCTURES
Volume 311, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.compstruct.2023.116808

Keywords

Mechanical buckling; 3D structure; Conductive composite; High sensitivity; Piezoresistive pressure sensor

Ask authors/readers for more resources

With the advancement of robotics and wearable devices, enhancing the sensitivity of piezoresistive pressure sensors to sense subtle stimuli has become crucial. This study introduces a 3D meso-structured sensor that exhibits significantly improved sensitivity compared to conventional 2D sensors, achieved through mechanical buckling assisted 3D structure formation. The sensor's sensitivity improvement is related to the developed tensile strain and its thickness can be adjusted for performance tuning.
With the advancement of robotics and wearable devices related research fields, enhancing the sensitivity of piezoresistive pressure sensor is the first demand of the related research to sense the subtle stimuli. To improve sensitivity, a material tailoring approach using the nature of different materials and an introduction of novel structures made by processing existing materials have been studied. Such latter mechanical exploration has the unique advantage of obtaining performance beyond the nature of the material. This study introduces a 3D meso-structured piezoresistive pressure sensor, which exhibits remarkably improved sensitivity of 450 times compared with that of a conventional 2D sensor, manufactured through simple mechanical buckling assisted 3D structure formation. The principle of sensitivity improvement is related to the developed tensile strain in the sensor and both numerical and experimental analyses show that the maximum principal strain plays a crucial role as a governing parameter to determine the sensitivity. Classical mechanics-based analyses further show that per-formances can be easily tuned by adjusting its thickness. The present sensor has excellent durability and reli-ability (stable over 10,000 operating cycles). Consequently, the use of a highly sensitive sensor with a digital twin application is demonstrated for real-time and virtual stress monitoring in a cantilever.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available