4.5 Article

Analytical Performance Evaluation for Estradiol using Liquid Chromatography-Tandem Mass Spectrometry

Journal

CLINICAL BIOCHEMISTRY
Volume 113, Issue -, Pages 59-63

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.clinbiochem.2023.01.003

Keywords

Estradiol; Ultra -performance liquid chromatography; Tandem mass spectrometry

Ask authors/readers for more resources

In this study, a highly sensitive and derivatization-free LC-MS/MS method was successfully developed for measuring estradiol levels in patients with estradiol-related endocrine disorders. The method showed good analytical performance and comparable results to a chemiluminescent microparticle immunoassay.
Background: There is an increased need for the sensitive and accurate measurement of estradiol levels in patients with estradiol-related endocrine disorders. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a reliable and accurate method for measuring steroid hormone levels. Here, we aimed to establish an LC-MS/MSbased method to quantify estradiol levels without sample derivatization and evaluated its analytical performance.Methods: Sciex Triple Quad 6500 + LC-MS/MS was used for estradiol analysis. We evaluated its analytical performance, including linearity, precision, the lower limit of detection and quantification (LoD and LoQ, respectively), accuracy, and carryover. The estradiol results determined by LC-MS/MS were compared with those obtained using a chemiluminescent microparticle immunoassay.Results: The LC-MS/MS output was linear for serum estradiol concentrations in the range of 0.2-10311.6 pmol/L. The intra-laboratory precision (coefficient of variation) was 3.0-10.1 %. The LoD and LoQ were 2.8 and 7.5 pmol/L, respectively. The overall accuracy was within 15 % of bias, and the carryover was within the acceptable range (<1.0 %). The results of the estradiol analysis determined by LC-MS/MS were comparable to those obtained by the chemiluminescent microparticle immunoassay (r(2) = 0.9843), although there was a negative bias of - 17.82 (95 % confidence interval, -27.21 to - 8.44).Conclusions: A highly sensitive, derivatization-free LC-MS/MS method was successfully developed in this study. This may be beneficial for estradiol measurements in patients with estradiol-related endocrine disorders.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available