4.4 Article

Acute Outflow Graft Occlusion-A Novel Predictable Complication of Lysis Therapy for the Treatment of Left entricular Assist Device Intra-Pump Thrombosis

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Missing the blind spot in a HeartMate 3 outflow graft obstruction caused by fungal infection

Christoph Hoermandinger et al.

Summary: A patient was admitted in cardiogenic shock with a suspected LVAD outflow obstruction, which was not confirmed by standard imaging but only revealed during a post-mortem examination. Despite the lack of confirmation from CT scan and angiography, a fungal thrombus formation was discovered as the cause of the outflow obstruction in the LVAD.

ARTIFICIAL ORGANS (2022)

Article Engineering, Biomedical

Interventional Procedures for Left Ventricular Assist Device-Associated Complications

Pia Lanmueller et al.

Summary: Interventional treatment approaches have become increasingly important in patients on long-term left ventricular assist device (LVAD), with promising outcomes in improving symptoms and complication management. However, there are also potential risks and complications associated with these procedures, including exacerbation of existing heart failure and procedural-related adverse events.

ASAIO JOURNAL (2022)

Article Cardiac & Cardiovascular Systems

The European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery: third report

Theo M. M. H. de By et al.

Summary: The study reviewed outcomes of patients receiving mechanical circulatory support in different implant eras, finding changes in patient characteristics and outcomes between periods. Overall, mortality, transplant rates, and probability of weaning at 5 years post-implant were 55%, 25%, and 2% respectively. Major infections mainly occurred in the early phase post-implant.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY (2022)

Article Cardiac & Cardiovascular Systems

Comparison of feasibility and results of frailty assessment methods prior to left ventricular assist device implantation

Luise Roehrich et al.

Summary: This study compared the feasibility and prognostic impact of different assessment tools in patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. The study found that bioelectrical impedance analysis parameters and CT measurements were suitable to predict 6-month mortality and/or prolonged ventilation time >95 h in patients with advanced heart failure.

ESC HEART FAILURE (2022)

Review Cardiac & Cardiovascular Systems

HVAD to HeartMate 3 Left Ventricular Assist Device Exchange: Best Practices Recommendations

Christopher T. Salerno et al.

Summary: The HeartWare HVAD System is being discontinued due to critical device malfunctions and higher risks, with patients being recommended to switch to the HeartMate 3 left ventricular assist system. This document discusses the differences between HVAD and HeartMate 3 in terms of medical management and technical aspects, providing evidence for best practices.

ANNALS OF THORACIC SURGERY (2022)

Article Cardiac & Cardiovascular Systems

The Society of Thoracic Surgeons Intermacs 2020 Annual Report

Ezequiel J. Molina et al.

Summary: The STS-Intermacs 2020 Annual Report analyzed data from 25,551 patients who underwent LVAD implantation between 2010 and 2019, revealing an increase in African American patients and a higher proportion bridged to durable LVAD with temporary mechanical support devices. The report also showed improvements in 1- and 2-year survival rates in the most recent era compared to the previous era, with major bleeding and infection remaining as leading adverse events.

ANNALS OF THORACIC SURGERY (2021)

Article Cardiac & Cardiovascular Systems

Outflow graft obstruction after left ventricular assist device implantation: a retrospective, single-centre case series

Akanksha Agrawal et al.

Summary: LVAD outflow graft obstruction is a relatively common yet underappreciated complication that can lead to recurrent heart failure and LVAD dysfunction. Outflow graft stenting can be achieved with low morbidity and provides a long-term solution to this complication.

ESC HEART FAILURE (2021)

Article Cardiac & Cardiovascular Systems

Safety of Contemporary Heart Failure Therapy in Patients with Continuous-Flow Left Ventricular Assist Devices

Jessica Kristin Schnettler et al.

Summary: Limited data are available concerning the safety, optimal administration, and benefits of contemporary heart failure therapy in LVAD patients. However, the study found that contemporary heart failure therapy is safe in LVAD patients, and there was no significant increase in serious adverse events in patients receiving ARNIs.

JOURNAL OF CARDIAC FAILURE (2021)

Article Engineering, Biomedical

Left Ventricular Assist Device Outflow Graft Obstruction: A Case Series

Sriram Nathan et al.

ASAIO JOURNAL (2020)

Article Engineering, Biomedical

Left ventricle assist device pulsatility index at the time of implantation is associated with follow-up pulmonary hemodynamics

Jacob J. Schaefer et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2020)

Article Cardiac & Cardiovascular Systems

Thrombolysis as first-line therapy for Medtronic/HeartWare HVAD left ventricular assist device thrombosis

Kamen Dimitrov et al.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY (2020)

Article Medicine, General & Internal

A Fully Magnetically Levitated Left Ventricular Assist Device - Final Report

M. R. Mehra et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Article Cardiac & Cardiovascular Systems

2019 EACTS Expert Consensus on long-term mechanical circulatory support

Evgenij V. Potapov et al.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY (2019)

Letter Cardiac & Cardiovascular Systems

Strategy for surgical correction and mitigation of outflow graft twist with a centrifugal-flow left ventricular assist system

Evgenij V. Potapov et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2018)

Article Cardiac & Cardiovascular Systems

HVAD: The ENDURANCE Supplemental Trial

Carmelo A. Milano et al.

JACC-HEART FAILURE (2018)

Article Cardiac & Cardiovascular Systems

Diagnosis and Treatment Algorithm for Blood Flow Obstructions in Patients With Left Ventricular Assist Device

Anna Mara Scandroglio et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2016)

Editorial Material Cardiac & Cardiovascular Systems

Stenting of an outflow graft obstruction after implantation of a continuous-flow, axial-flow left ventricular assist device

Duc Thinh Pham et al.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2015)

Article Engineering, Biomedical

Acoustic Spectral Analysis for Determining Pump Thrombosis in Rotary Blood Pumps

Friedrich Kaufmann et al.

ASAIO JOURNAL (2014)

Editorial Material Cardiac & Cardiovascular Systems

Use of polytetrafluoroethylene vascular graft to cover the kinking protector of left ventricular assist device facilitates later pump exchange

Evgenij V. Potapov et al.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2014)

Article Engineering, Biomedical

Design Concepts and Principle of Operation of the HeartWare Ventricular Assist System

Jeffrey A. LaRose et al.

ASAIO JOURNAL (2010)