4.7 Article

Design and off-design performance analysis of a liquid carbon dioxide energy storage system integrated with low-grade heat source

Journal

APPLIED THERMAL ENGINEERING
Volume 228, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.120570

Keywords

Liquid carbon dioxide energy storage; Off-design performance; Supercritical; Low-grade heat source

Ask authors/readers for more resources

Nowadays, the development of renewable energy has become a global consensus. However, the intermittent and volatile nature of renewable electricity presents challenges to grid stability. Liquid carbon dioxide energy storage is recognized as a promising technology to address these difficulties. This paper proposes a liquid carbon dioxide energy storage system integrated with a low-grade heat source, and investigates system design and performance under both design and off-design conditions.
Nowadays, developing the renewable energy has become the worldwide consensus. Nevertheless, the intermit-tency and volatility of renewable electricity bring great challenges to the stability of the power grid. Liquid carbon dioxide energy storage is recognized as one of the most promising technologies to overcome these dif-ficulties. In this paper, a liquid carbon dioxide energy storage system integrated with the low-grade heat source is proposed. Based on the preliminary geometric parameters of system components, investigations on the system design and off-design performances are carried out. Results of parametric analysis indicate that the pseudo -critical point corresponding to 8 MPa is recommended as the design point for compressor inlet, and the mini-mum value of LCOE could reach 9.49 cents/kWh. Under design conditions, the system exergy efficiency reaches 48.42% and the roundtrip efficiency is 63.60%. Moreover, 10.70 cents/kWh of the per unit generation cost is advantageous in the large-scale energy storage systems. With the variations of input power (70%-120%) and output power level (50%-100%), the surplus water ratio could reach 23.63% at 50% load level, while the variation range of exergy efficiency is 15.56%-48.42%. Meanwhile, the roundtrip efficiency varies from 22.16% to 63.60% under off-design conditions, and the maximum value is achieved at the design point. All the results identify the feasibility of the integrated energy storage system.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available