4.5 Article

Validating MRI-Derived Myocardial Stiffness Estimates Using In Vitro Synthetic Heart Models

Journal

ANNALS OF BIOMEDICAL ENGINEERING
Volume 51, Issue 7, Pages 1574-1587

Publisher

SPRINGER
DOI: 10.1007/s10439-023-03164-7

Keywords

Cardiac mechanics; Cardiac MRI; Heart failure; 3D printed phantom; In vitro MRI; Passive myocardial stiffness; Hyperelastic materials

Ask authors/readers for more resources

Impaired cardiac filling in heart failure is caused by increased passive myocardial stiffness. In this study, we used inverse finite element analysis based on MRI and pressure data to estimate in vivo passive myocardial stiffness. Soft and stiff heart phantoms were created using 3D printing and their stiffness was accurately estimated. The results suggest that MRI-driven computational modeling can accurately estimate synthetic heart material stiffness in a certain range.
Impaired cardiac filling in response to increased passive myocardial stiffness contributes to the pathophysiology of heart failure. By leveraging cardiac MRI data and ventricular pressure measurements, we can estimate in vivo passive myocardial stiffness using personalized inverse finite element models. While it is well-known that this approach is subject to uncertainties, only few studies quantify the accuracy of these stiffness estimates. This lack of validation is, at least in part, due to the absence of ground truth in vivo passive myocardial stiffness values. Here, using 3D printing, we created soft, homogenous, isotropic, hyperelastic heart phantoms of varying geometry and stiffness and simulate diastolic filling by incorporating the phantoms into an MRI-compatible left ventricular inflation system. We estimate phantom stiffness from MRI and pressure data using inverse finite element analyses based on a Neo-Hookean model. We demonstrate that our identified softest and stiffest values of 215.7 and 512.3 kPa agree well with the ground truth of 226.2 and 526.4 kPa. Overall, our estimated stiffnesses revealed a good agreement with the ground truth (< 5.8% error) across all models. Our results suggest that MRI-driven computational constitutive modeling can accurately estimate synthetic heart material stiffnesses in the range of 200-500 kPa.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available