4.8 Article

Ratiometric Fluorescence Sensing System for Lead Ions Based on Self-Assembly of Bioprobes Triggered by Specific Pb2+-Peptide Interactions

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 15, Issue 11, Pages 14131-14145

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.3c00567

Keywords

lead; ratiometric; probe; fluorescent; sensor; Pb2+

Ask authors/readers for more resources

In this study, fluorescent probes for ratiometric detection of Pb2+ in aqueous solution and living cells were developed based on Peptide receptors. Through the synthesis and investigation of different fluorescent probes, benzothiazolyl-cyanovinylene was determined as an appropriate fluorophore for ratiometric detection of Pb2+. Furthermore, by modifying the peptide receptors, two fluorescent probes with remarkable ratiometric sensing properties for Pb2+ were developed.
Lead is one of the most toxic substances. However, there are few ratiometric fluorescent probes for sensing Pb2+ in aqueous solution as well as living cells because specific ligands for Pb2+ ions have not been well characterized. Considering the interactions between Pb2+ and peptides, we developed ratiometric fluorescent probes for Pb2+ based on the peptide receptor in two steps. First, we synthesized fluorescent probes (1-3) based on the tetrapeptide receptor (ECEE-NH2) containing hard and soft ligands by conjugation with diverse fluorophores that showed excimer emission when they aggregated. After investigation of fluorescent responses to metal ions, benzothiazolyl-cyanovinylene was evaluated as an appropriate fluorophore for ratiometric detection of Pb2+. Next, we modified the peptide receptor to decrease the number of hard ligands and/or to replace Cys with disulfide bond and methylated Cys for improving selectivity and cell permeability. From this process, we developed two fluorescent probes (3 and 8) among the probes (1-8) that exhibited remarkable ratiometric sensing properties for Pb2+ including high water solubility (<= 2% DMF), visible light excitation, high sensitivity, selectivity for Pb2+, low detection limits (<10 nM), and fast response (<6 min). The binding mode study revealed that specific Pb2+-peptide interactions of the probes caused nanosized aggregates in which the fluorophores of the probes came close each other, exhibiting excimer emission. In particular, 8 based on tetrapeptide bearing a disulfide bond and two carboxyl groups with a good permeability successfully quantified intracellular uptake of Pb2+ in live cells through ratiometric fluorescent signals. The ratiometric sensing system based on specific metal-peptide interactions and excimer emission process could provide a valuable tool to quantify Pb2+ in live cells and pure aqueous solutions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available