3.8 Article

Humoral Responses in the Omicron Era Following 3-Dose SARS-CoV-2 Vaccine Series in Kidney Transplant Recipients

Journal

TRANSPLANTATION DIRECT
Volume 9, Issue 1, Pages -

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/TXD.0000000000001401

Keywords

-

Ask authors/readers for more resources

Kidney transplant recipients (KTRs) have a diminished response to SARS-CoV-2 vaccination and over 50% of KTRs lack Omicron-specific neutralization capacity one month after receiving the third mRNA vaccine dose. Antibody levels of responders were well preserved at three months. Anti receptor binding domain antibody titers may be a key indicator for detecting patients with a detectable Omicron-neutralizing antibody response.
BackgroundKidney transplant recipients (KTRs) have a diminished response to SARS-CoV-2 vaccination compared with immunocompetent individuals. Deeper understanding of antibody responses in KTRs following third-dose vaccination would enable identification of those who remain unprotected against Omicron. MethodsWe profiled antibody responses in KTRs pre- and at 1 and 3 mo post-third-dose SARS-CoV-2 mRNA-based vaccine. Binding antibody levels were determined by ELISA. Neutralization against wild type, Beta, Delta, and Omicron (BA.1) variants was determined using a SARS-CoV-2 spike-pseudotyped lentivirus assay. ResultsForty-four KTRs were analyzed at 1 and 3 mo (n = 26) post-third dose. At 1 mo, the proportion of participants with a robust antibody response had increased significantly from baseline, but Omicron-specific neutralizing antibodies were detected in just 45% of KTRs. Median binding antibody levels declined at 3 mo, but the proportion of KTRs with a robust antibody response was unchanged; 38.5% KTRs maintained Omicron-specific neutralization at 3 mo. No clinical variables were significantly associated with Omicron-neutralizing antibodies, but antireceptor binding domain titers appeared to identify those with Omicron-specific neutralizing capacity. Conclusions.Over 50% of KTRs lack Omicron-specific neutralization capacity 1 mo post-third mRNA-vaccine dose. Antibody levels of responders were well preserved at 3 mo. Anti receptor binding domain antibody titers may identify patients with a detectable Omicron-neutralizing antibody response.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available