4.5 Article

Direct immersion solid-phase microextraction with gas chromatography and mass spectrometry for the determination of specific biomarkers of human sweat in melted snow

Journal

JOURNAL OF SEPARATION SCIENCE
Volume 39, Issue 7, Pages 1300-1309

Publisher

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201501097

Keywords

Biomarkers; Human sweat; Melted snow; Solid-phase microextraction

Funding

  1. Fondazione per l'Universita e l'Alta Cultura in Provincia di Belluno
  2. FP-7 [285446]

Ask authors/readers for more resources

To provide a reliable tool for investigating diffusion processes of the specific components of the human odor 3-hydroxy-3-methylhexanoic acid and 3-methyl-3-sulfanylhexan-1-ol through the snowpack, we developed and optimized an analytical method based on direct immersion solid-phase microextraction followed by gas chromatography with mass spectrometry. Direct immersion solid-phase microextraction was performed using polyacrylate fibers placed in aqueous solutions containing 3-hydroxy-3-methylhexanoic acid and 3-methyl-3-sulfanylhexan-1-ol. After optimization, absorption times of 120 min provided a good balance to shorten the analysis time and to obtain suitable amounts of extractable analytes. The extraction efficiency was improved by increasing the ionic strength of the solution. Although the absolute extraction efficiency ranged between 10 and 12% for 3-hydroxy-3-methylhexanoic acid and 2-3% for 3-methyl-3-sulfanylhexan-1-ol, this method was suitable for analyzing 3-hydroxy-3-methylhexanoic acid and 3-methyl-3-sulfanylhexan-1-ol concentrations of at least 0.04 and 0.20 ng/mL, respectively. The precision of the direct immersion solid-phase microextraction method ranged between 8 and 16%. The variability within a batch of six fibers was 10-18%. The accuracy of the method provided values of 88-95 and 86-101% for 3-hydroxy-3-methylhexanoic acid and 3-methyl-3-sulfanylhexan-1-ol, respectively. The limit of detection (and quantification) was 0.01 ng/mL (0.04 ng/mL) for 3-hydroxy-3-methylhexanoic acid and 0.06 ng/mL (0.20 ng/mL) for 3-methyl-3-sulfanylhexan-1-ol. The signal versus concentration was linear for both compounds (r(2) = 0.973-0.979). The stability of these two compounds showed that 3-hydroxy-3-methylhexanoic acid was more stable in water than 3-methyl-3-sulfanylhexan-1-ol. We applied the method to environmental samples in correspondence with an olfactory target buried previously.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available