4.7 Article

Radiation Exposure and Surgical Outcomes after Antegrade Sclerotherapy for the Treatment of Varicocele in the Paediatric Population: A Single Centre Experience

Journal

JOURNAL OF CLINICAL MEDICINE
Volume 12, Issue 3, Pages -

Publisher

MDPI
DOI: 10.3390/jcm12030755

Keywords

varicocele; paediatric varicocele; antegrade sclerotherapy; Tauber procedure; male infertility; radiation exposure; fluoroscopy

Ask authors/readers for more resources

In this study, the researchers evaluated the radiation exposure and surgical outcomes after the Tauber procedure for varicocele treatment. They found that the procedure was safe and associated with low radiation doses. However, operative time and the patient's body mass index were predictors of higher radiation dose.
Introduction: Antegrade sclerotherapy (Tauber) effectively treats varicocele. However, fluoroscopy exposes young males to ionizing radiation. We aimed to evaluate radiation exposure and surgical outcomes after the Tauber procedure. Materials and methods: We retrospectively analysed data from 251 patients. Dose area product (DAP) and fluoroscopy time were recorded. The effective dose was calculated with the PCXMC software. Descriptive statistics and linear regression tested the association between clinical predictors and radiation exposure. Results: Median (IQR) age and body mass index (BMI) were 14 (13-16) years and 20.1 (17.9-21.6) kg/m(2). Five (2.1%) patients developed clinical recurrence and two (0.81%) developed complications. Median fluoroscopy time and DAP were 38.5 (27.7-54.0) s and 89.6 (62.5-143.9) cGy*cm(2). The effective dose was 0.19 (0.14-0.31) mSv. Fluoroscopy time was higher in patients with collateral veins (41 (26-49) s vs. 36 (31-61) s, p = 0.02). The median amount of sclerosing agent (SA) used was 3 (3-4) ml. DAP was higher when SA > 3 mL was used (101.4 (65-183) cGy*cm(2) vs. 80.5 (59-119) cGy*cm(2); p < 0.01). At univariable linear regression, age, BMI, operative time and SA > 3 mL were associated with higher DAP (all p < 0.01). At multivariable linear regression, only BMI (beta 12.9, p < 0.001) and operative time (beta 1.9, p < 0.01) emerged as predictors of higher DAP, after accounting for age and SA > 3 mL. Conclusions: The Tauber procedure is safe and associated with low effective doses. Operative time and the patient's BMI independently predict a higher radiation dose.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available